Back to search

Institutional Repository of Vilnius University

Spausdintų aukso elektrodų taikymas sunkiųjų metalų nustatymui ciklinės voltamperometrijos būdu /

Abstract

dc:description

SUMMARY VILNIUS UNIVERSITY FACULTY OF CHEMISTRY AND GEOSCIENCES DIANA KAUŠPĖDIENĖ Application of Screen-Printed Gold Electrodes for Heavy Metals Detection by Means of Cyclic Voltammetry The present paper describes the application of a gold-based screen-printed sensor to individual and simultaneous detection of heavy metals (copper, lead, tin and zinc) using cyclic voltammetry (CV) technique. The research was conducted in collaboration with JSC “Elektronikos Perdirbimo Technologijos” (Vilnius, Lithuania). Thus, the aim and objectives of this study were adapted to the needs of the company. Screen-printed gold electrodes (model 220AT) were purchased from DropSens (Spain). Working (4 mm diameter) and counter electrodes were made of gold, whereas reference electrode and electric contacts were made of silver. CV studies were recorded on the screen printed electrodes using a potentiostat/galvanostat AUTOLAB302 controlled by GPES software. Trisodium Citrate solution 0.38 mol/l was used as the support electrolyte. All measurements were conducted at room temperature. In the first part of the thesis the optimization of the operating CV parameters, such as the scan rate, the cathodic potential and the metal ion concentration effect, was studied. It was found that clearly distinct peaks are visible when the scan rate is 10 mV/s (for Cu2+, Pb2+ and Sn2+) and 50 mV/s for Zn2+ solution. Therefore, the studied cyclic voltamogramms have shown that the anodic current of the Cu2+, Pb2+, Sn2+ and Zn2+ ions increases proportionally with the increase in the cathodic potential. A linear response of anodic peak currents was observed for Cu2+ concentration in the range from 0,01 M to 0,15 M, for Pb2+ – in the range from 0,01 M to 0,04 M, for Sn2+ – in the range from 0,01 M to 0,03 M, Zn2+ – from 0,02 M to 0,10 M. The detection limits of Cu2+, Pb2+, Sn2+ and Zn2+ were 7,1 ∙ 10-7 M, 1,5 ∙ 10-7 M, 5,2 ∙ 10-7 M and 2,5 ∙ 10-7 M, respectively. Meanwhile the sensitivity values decrease in the row Pb2+ >Zn 2+ > Sn2+ > Cu2+. Moreover it was found that the investigated screen-printed gold electrodes have a great potential to be used in the development of portable analyzers for simultaneous determination of the Cu2+, Pb2+ and Zn2+ ions in mixed solutions (Cu2+ and Pb2+; Cu2+ and Zn2+) in a single run. However, due to similar properties in the electroanalysis of tin Cu2+ and Sn2+ the voltammograms of copper and tin overlap and it is difficult to simultaneously determine these two metals.

Degree

thesis:*
Grantor dc:publisher
Institutional Repository of Vilnius University
Year dc:date
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kaušpėdienė, Diana,

Rights

dc:rights
Statement dc:rights
  • info:eu-repo/semantics/openAccess
Language dc:language
lit

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Vilnius University
Base URL
epublications.vu.lt/oai
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Kaušpėdienė, Diana,. Spausdintų aukso elektrodų taikymas sunkiųjų metalų nustatymui ciklinės voltamperometrijos būdu /. Institutional Repository of Vilnius University, 2020. https://repository.vu.lt/VU:ELABAETD193301551&prefLang=en_US