Institutional Repository of Vilnius University
Skaidulinių scintiliatorių optinių savybių tyrimas /
Abstract
dc:descriptionThe main purpose of this work was to evaluate the quality of the growing method and the reproducibility of Cerium doped Gadolinium Aluminum Gallium Garnet (GAGG:Ce) fiber shaped scintillators. The task was to measure the spatial distribution of photoluminescence spectra of the samples with a confocal microscope and to evaluate the distribution of impurities in fiber scintillators. All studies were carried out at Vilnius University Institute of Photonics and Nanotechnology.Five identical GAGG:Ce specimens with dimensions 1x1x100mm were used for the experiment. Initially, intensity measurements were performed at four crystal positions - in the center of the cross-section, about one centimeter from the left and right edges, and in the center, along the crystalline fibers. The results showed that the values of intensity do not depend on the place of measurement. Luminescence intensity at the surface of the sample is evenly distributed. After measuring the luminescence spectra, we found that the maximum intensity in all samples was approximately 543nm. Furthermore, the attenuation length of the samples was also measured. A special stand was made to carry out this experiment. A sample was placed on the rail to which a fiber optic was attached on one side. In this way, we were able to measure the photoluminescence intensity profile aloing the sample.. After calculating attenuation lengths of all samples, we obtained that the attenuation lengths of all samples coincide within the error values, and the average length of attenuation of the samples is 27.5 cm. This is a good result because the attenuation length of the scintillators used in electromagnetic calorimeters is usually between 15 and 30 centimeters. By measuring the photoluminescence intensities of the samples, we have noticed certain strips which were attributed to the variation of the growth conditions. However, by analysing the center of the band position, we conclude that the fluctuations of the concentration of impurities are insignificant. This is also supported by the light attenuation length measurements, which would be greatly reduced even at low fluctuations of the concentration.
Degree
thesis:*- Grantor dc:publisher
- Institutional Repository of Vilnius University
- Year dc:date
- 2019
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Kučinskas, Jonas Algirdas,
Rights
dc:rights- Statement dc:rights
-
- info:eu-repo/semantics/openAccess
- Language dc:language
- lit
Identifiers
dc:identifier.*- Repository record dc:identifier
- https://repository.vu.lt/VU:ELABAETD193351663&prefLang=en_US