Institutional Repository of Vilnius University
Nereceptinių vaistų metabolitų aptikimas žmogaus ašarose paviršiaus sustiprintos Ramano sklaidos metodu /
Abstract
dc:descriptionStudent: Luka Jonaitytė DETECTION OF OVER THE COUNTER DRUG TRACES IN HUMAN TEARS USING SURFACE ENHANCED RAMAN SCATTERING. The aim of this work is to assess the suitability of surface enhanced Raman Scattering (SERS) method for detecting low concentrations of salicylic acid in human tears. To reach the aim, tasks were set as follows: 1. Prepare layers of silver nanoparticles that effectively enhance Raman scattering using prepared colloidal solution. 2. Register surface enhanced Raman scattering spectra of different concentration salicylic acid solutions. 3. Register surface enhanced Raman scattering spectra of synthetic tears mixed with different concentration salicylic acid solutions. 4. Perform the analysis of the recorded spectra and determine the suitability of the SERS methodology for salicylic acid detection in synthetic tears. The coursework presents how the colloidal solution of silver nanoparticles was prepared, how individual samples of different concentrations of salicylic acid solutions as well as their mixtures with synthetic tears samples were prepared for surface enhanced Raman scattering measurements. After the silver nanoparticulate colloidal solution was prepared, it was greenish-yellow in color, the UV-VIS absorption spectrum peak was at 420 nm. From the absorption spectra of the colloidal solution, it was determined that the absorption optical density at 1064 nm (the wavelength of the laser used to excite Raman scattering) was unequal to 0. Therefore, colloid was suitable for SERS studies with 1064 nm laser. After recording the Raman spectra of saturated salicylic acid aqueous solution, it was determined that the method was not sensitive enough for spectral band detection in salicylic acid solution. A calibration curve was calculated and made from different concentrations salicylic acid surface enhanced Raman scattering spectra. Calibration curve up to 10 mM integral, the concentration dependence is linear and from 10 mM the calibration curve becomes saturated due to insufficient adsorption sites near the silver nanoparticles. It has been found that the minimum concentration of salicylic acid that can be reliably detected in mixtures of synthetic tears and salicylic acid at different concentrations is from 2 mM.
Degree
thesis:*- Grantor dc:publisher
- Institutional Repository of Vilnius University
- Year dc:date
- 2019
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Jonaitytė, Luka,
Rights
dc:rights- Statement dc:rights
-
- info:eu-repo/semantics/openAccess
- Language dc:language
- lit
Identifiers
dc:identifier.*- Repository record dc:identifier
- https://repository.vu.lt/VU:ELABAETD193352129&prefLang=en_US