Back to search

Institutional Repository of Vilnius University

Bandinio temperatūros įtaka skaidrių medžiagų femtosekundiniu lazeriu indukuotos plazmos spektroskopinių tyrimų parametrams /

Abstract

dc:description

Laser-induced breakdown spectroscopy (LIBS) is an analytical atomic spectrometry technique, valued for numerous advantageous analytical and technical characteristics. We can get qualitative and quantitative analytical information for any sample in any state of aggregation fast and without any substantial sample preparation. With LIBS we can do on-site noncontact analysis of difficult-to-reach or hazardous samples. On the other hand, without a lot of advantages, there are some challenges, which limits wide appliance of this technique. Limits of detection most of the time lag behind those of many laboratory techniques and standart deviations are quite significant. One of the important factors, trying to improve quality of LIBS, is sample parameters. In this study, there was conducted an experiment, where plasma was excited by femtosecond laser with single impulses and multi-pulses with different energy distribution between impulses. Investigations in this work are aimed to investigate the influence of initial sample temperature for spectral line Na I (589 nm) signal/noise ratio. Plasma was excited with three different laser energies - 70 µJ, 60 µJ ir 41 µJ. Spectral lines was registered by spectrometer and line Na I (589 nm) was investigated. The signal/noise ratio of spectral line Na I (589 nm) was dependent from sample temperature, it was increased. With single pulses increase was approximately 1,3 times, while increase using multi-pulse regime was the same with all three different distributions between pulses and it was approximately 1,5 times. Both using multi-pulse regime and increasing sample temperature, signal/noise ratio of spectral line Na I (589 nm) increased 2,7 times comparing with the one excited by single pulse when sample temperature - 240 C. To conclude, we can get significant increase of spectral intensity (signal/noise ratio) while using multi-pulse regime and increasing sample temperature. This can be used expanding the limits of detection and analytical sensitivity.

Degree

thesis:*
Grantor dc:publisher
Institutional Repository of Vilnius University
Year dc:date
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Onaitis, Domantas,

Rights

dc:rights
Statement dc:rights
  • info:eu-repo/semantics/openAccess
Language dc:language
lit

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Vilnius University
Base URL
epublications.vu.lt/oai
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Onaitis, Domantas,. Bandinio temperatūros įtaka skaidrių medžiagų femtosekundiniu lazeriu indukuotos plazmos spektroskopinių tyrimų parametrams /. Institutional Repository of Vilnius University, 2019. https://repository.vu.lt/VU:ELABAETD193354174&prefLang=en_US