Institutional Repository of Vilnius University
Šviesos saviveikos reiškinių stipriai sklaidančiose terpėse tyrimas /
Abstract
dc:descriptionSupercontinuum generation in scattering and absorbing media is quite complicated due to numerous nonlinear optics phenomena. The lack of ballistic photons is lowering probability of spectrum broadening in scattering media due to many scattering phenomena. In this paper media with different transmittances were analyzed – supercontinuum spectrums were registered and analyzed. Four glasses with different transmittance were selected: BK-7 glass with transmittance of 88%, neutral, colored glasses with transmittance values of 36,5%, 13,5% and 4,2%. Transmittance of each glass was registered with bandwidth of 2000 nm. Also, the number of ballistic photons in MS-23 glass was registered and had a value of 0,46% of the initial value of ballistic photons. Using a wavelength of 2000 nm were pump energy reached 30,5 μJ, the spectrums diagrams were obtained from which it could be seen that form of spectral dynamics, in principle, are the same in glasses which have transmittance bigger than 13,5%, but in different media the level of energy, at which spectrum broadening could be seen, varies. Supercontinuum generation in BK-7 and neutral colored glasses begins at 2,25 μJ, 3,75 μJ and 6,15 μJ respectively. Second spectrum broadening occurs at 4,5 μJ, 7,45 μJ and 12,73 μJ respectively. In MS-23 media spectrum broadening occurs when pulse energy of 10 μJ is reached, but second spectrum broadening is not detected, even though, the pulse energy reached value of 30 μJ. In the second part of the study the time resoled 3D mapping measurements were performed and filaments formation in media with different transmittance was analyzed. While spectrums are broadened it could be seen that few and more pulses occur and later new filaments are formed. There is no clear dependency between energy values of spectrum broadening and transmittance, but one conclusion could be made: approximately, in media which has transmittance higher than 13,5% the energy values of spectrum broadening have exponential dependency with transmittance. When focus sharpness is slightly changed in media with lower transmittance, the scattering of energy values of spectrum broadening increasing drastically. This study showed that even with high losses of energy the spectrum broadening could be seen and statement that supercontinuum is generated, could be made, but the extent and causes of spectrum broadening is different compared to almost transparent media.
Degree
thesis:*- Grantor dc:publisher
- Institutional Repository of Vilnius University
- Year dc:date
- 2019
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Glazkov, Vitalij,
Rights
dc:rights- Statement dc:rights
-
- info:eu-repo/semantics/openAccess
- Language dc:language
- lit
Identifiers
dc:identifier.*- Repository record dc:identifier
- https://repository.vu.lt/VU:ELABAETD193354307&prefLang=en_US