Back to search

Institutional Repository of Vilnius University

Rankos trifalangių pirštų grafinės popieriaus juostų ir standartinės goniometrijos tarpusavio pakeičiamumas ir jo reikšmė savityrai /

Abstract

dc:description

Research problem Diagrammatic evaluation of finger joint angles by using two folded paper strips could be a quick alternative to the standard goniometry and a means for self-evaluation. Reliability of the paper strip technique has not been explored. Methods This research compared reliability characteristics of repeated measurements obtained with both tools by employing (1) 24 healthy medical students to act interchangeably as subjects and raters and (2) 61 patients and a professional rater. The healthy subjects used special guides to position their ring finger joints at varying angles. The patients, without considerable preparation, self-evaluated active extension of the filth finger with paper strips, and the practitioner performed parallel evaluations with both tools. The diagrams of joint angles were scanned and measured. Results In the non-clinical study, reliability was similar for both tools. Intrarater and interrater intraclass correlation coefficients (ICC) ranged from 0.69 to 0.93, and the standard errors of measurements ranged from 2.4º to 4.9º. In the clinical study, for proximal interphalangeal joints, intrarater ICCs were above 0.99, and Interrater (patient versus rater) ICCs were below 0.033. However, the proportions of the acceptable absolute ≤5 differences between all paired practitioner’s measurements were equivalent. The proportions of interrater ≤5 differences were nonequivalent for the interphalangeal joints. Conclusions The paper strip and standard goniometry can be used interchangeably for finger joints. Patients’ performance in extempore self-evaluation is clinically inadequate. Further studies are necessary to explore whether appropriate training of patients can improve consistency of diagrammatic self-evaluation.

Degree

thesis:*
Grantor dc:publisher
Institutional Repository of Vilnius University
Year dc:date
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Mačionis, Valdas,

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • info:eu-repo/semantics/openAccess
Language dc:language
lit

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Vilnius University
Base URL
epublications.vu.lt/oai
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Mačionis, Valdas,. Rankos trifalangių pirštų grafinės popieriaus juostų ir standartinės goniometrijos tarpusavio pakeičiamumas ir jo reikšmė savityrai /. Institutional Repository of Vilnius University, 2013. https://repository.vu.lt/VU:ELABAETD2095993&prefLang=en_US