Back to search

Institutional Repository of Vilnius University

Patalpų oro taršos tyrimas taikant paprastuosius oro kokybės jutiklius /

Abstract

dc:description

The analysis of the low-cost air quality sensors was carried out in two stages. AIRWINGS sensor data began to be collected October 2023, LSA – in February 2024. A reliability study of AIRWINGS and LSA air quality sensors showed that they measure CO2 and PM2.5 concentrations accurately enough for air quality studies. However, systematic errors need individual evaluation. AIRWINGS sensors had PM2.5 concentration error of about 15 % of the average PM2.5, while LSA sensors had an average CO2 error of ± 57,8 ppm, with a maximum error of 99 ppm (22,7 % of the average CO2). LSA sensors displayed narrower data dispersion and higher repeatability compared to AIRWINGS sensors. After the reliability study of the sensor measurements, the devices were moved to one of the schools located in the center of Vilnius, where indoor and outdoor aerosol particles and gaseous compounds concentration measurements were performed in order to analyze and determine the characteristic dynamics parameters. During March 11 - 25 2024, the average outdoor PM2.5 concentration was 15,6 μg/m³, and 5,5 μg/m³ inside a classroom, indicating a PM2.5 infiltration ratio of 30 %. The average indoor CO2 concentration was 705 ppm, that is 1,6 times higher than outdoors (435 ppm). Both PM2.5 and CO2 levels were within acceptable limits. At night, the indoor/outdoor PM2.5 concentration ratio (I/O) decreases due to reduced indoor activity, whereas during the day - the opposite. PM2.5 levels drop within an hour after closing windows, and CO2 levels decrease within three hours after classes end. The air renewal rate for PM2.5 particles is 0,27 h⁻¹, and for CO2, it is 0,3 h⁻¹. Analysis of indoor and outdoor aerosol particles and gas concentrations supported a strong correlation between outdoor and indoor PM2.5 levels, indicating that the outdoor air is the primary source of PM2.5 indoors. For CO2, human activity is the main source inside the school, with levels decreasing to outdoor values after school hours.

Degree

thesis:*
Grantor dc:publisher
Institutional Repository of Vilnius University
Year dc:date
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Juozapaitytė, Ieva,

Rights

dc:rights
Statement dc:rights
  • info:eu-repo/semantics/openAccess
Language dc:language
lit

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Vilnius University
Base URL
epublications.vu.lt/oai
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Juozapaitytė, Ieva,. Patalpų oro taršos tyrimas taikant paprastuosius oro kokybės jutiklius /. Institutional Repository of Vilnius University, 2024. https://repository.vu.lt/VU:ELABAETD210578695&prefLang=en_US