Institutional Repository of Vilnius University
Elektrocheminė paracetamolio analizė /
Abstract
dc:descriptionIn this thesis, a solution of paracetamol is investigated using a modified glassy carbon electrode (GCE). Paracetamol was chosen as the subject of the study because it is a widely used in medicine for pain and fever relief around the world, and it has been detected in both wastewater and fresh water sources in various studies. The fact that paracetamol is worthy of attention is also shown by the fact that there are a number of studies that have evaluated the effects of paracetamol on both fresh and salt water plants and organisms – from bacteria to fish. First of all, not modified GCE was studied by electrochemical analysis methods – cyclic voltammetry (CV), square wave voltammetry (SWV) and chronoamperometry (ChA) methods were used for this purpose. With the help of CV, it was observed that the reactions take place due to diffusion, therefore, using the Randles - Ševčik equation, the electroactive area of the not modified electrode was calculated, which is equal to 0,0553 cm2 (geometric area of the electrode 0,071 cm2). The electrode was modified with two vitamins – at first, polyfolate (vitamin B9) and then polyriboflavin (vitamin B2). On the surface of the polymerized GCE in both cases, the reactions with polyfolate and polyriboflavin also took place due to diffusion, the electroactive areas were calculated according to the same principle as for the clean one, and it was observed that the electroactive areas decrease at least twice – 0,0191 and 0,0244 cm2 were obtained, respectively. According to the obtained results, it can be concluded that GCE with polyfolate is much more sensitive for testing paracetamol concentration by square wave voltammetry method than chronoamperometry. It was observed that GCE with polyriboflavin is much more sensitive when testing paracetamol by the square wave voltammetry method, but when tested by this method, the sensitivity was only slightly increased compared to not modified GCE. The work shows that these two vitamins used for polymerization are suitable for GCE modification and paracetamol detection. Monitoring the change in sensitivity over time shows that polyfolate-modified GCE is more stable than polyriboflavin-modified GCE.
Degree
thesis:*- Grantor dc:publisher
- Institutional Repository of Vilnius University
- Year dc:date
- 2024
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Mikutytė, Ema,
Rights
dc:rights- Statement dc:rights
-
- info:eu-repo/semantics/openAccess
- Language dc:language
- lit
Identifiers
dc:identifier.*- Repository record dc:identifier
- https://repository.vu.lt/VU:ELABAETD210580661&prefLang=en_US