Institutional Repository of Vilnius University
Impedimetrinio biojutiklio, skirto SARS-CoV-2 antikūnams aptikti, kūrimas ir tyrimas /
Abstract
dc:descriptionThe aim of the bachelor’s thesis was to develop and test a biosensor with the SARS-CoV-2 spike protein as the bioreceptor and antibodies to SARS-CoV-2 antigen in human serum as the analyte. The biosensor was evaluated using electrochemical impedance spectroscopy. Positive analytical signal values were recorded when the biosensor was exposed to solutions of serum from immunised human subject; the increase in these signals may be due to an immunochemical reaction between the sensor bioreceptor and the analyte in the medium, but further control studies which were performed using background medium solutions also recorded an increase in the analytical signal. To improve the specificity of the biosensor for the analyte, additional surface blocking tests with bovine serum albumin (BSA) solutions were performed. After determining the optimal BSA concentration and blocking time parameters, additional control measurements were performed, and the results showed that the optimised BSA blocking procedure did not significantly improve the specificity of the sensor for the analyte. The assembly and control testing of a sensor without a bio-recognition element also resulted in increasing analytical signal values. The electrode of a used sensor was regenerated to investigate the possibility of reusing the same sensing glass electrodes multiple times. The measurements of the reassembled sensor, which used a regenerated electrode, showed an increase in the analytical signals of the resulting sensor compared to the data of the same sensor before the regeneration of the conductive surface. Based on these findings, it was determined that the electrode washing and preparation procedure may not be sufficient enough to effectively regenerate spent electrodes or more likely that the protein crosslinking with glutaraldehyde is a far too flawed procedure. Based on the collected data and its findings, it is concluded that the utilised biorecognition element of the biosensor is not sufficiently effective for the analyte or that the analyte medium exerts an excessive influence in distinguishing between background and analytical signals. Furthermore, the procedure used for washing and preparation of the electrode may not be sufficiently effective to ensure full regeneration of the biosensing surface. Lastly, the bioreceptor immobilisation by glutaraldehyde vapour is too difficult of a process to successfully control and replicate.
Degree
thesis:*- Grantor dc:publisher
- Institutional Repository of Vilnius University
- Year dc:date
- 2024
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Pirštelis, Domas,
Rights
dc:rights- Statement dc:rights
-
- info:eu-repo/semantics/openAccess
- Language dc:language
- lit
Identifiers
dc:identifier.*- Repository record dc:identifier
- https://repository.vu.lt/VU:ELABAETD210580792&prefLang=en_US