Back to search

Institutional Repository of Vilnius University

Akinių lęšių periferinio astigmatizmo tyrimas /

Abstract

dc:description

Aim of the work: to analyze peripheral astigmatism in the selected ophthalmic lenses. Tasks of the work: to analyze the research and training literature about the ophthalmic lenses, lens characteristics and lens aberrations; to analyze characteristics of the optometric device (dioptrimeter) and its application in measuring the ophthalmic lenses; to carry out the experimental study of the ophthalmic lenses using the dioptrimeter with the aim to assess peripheral astigmatism. Methods of the work: analysis of research literature; experimental study of peripheral astigmatism in ophthalmic lenses using the control optometric device (dioptrimeter), and data processing with “Microsoft” Excel 2016 software application. A special add-on to the dioptrimeter to simulate position of the lens in point of the eye was constructed for the purpose of the study. Measurements of the ophthalmic lenses selected for the study were taken at the centre of the lens and peripherally. The base curves of the lenses were measured using the spherometer. Characteristics of the lens that is, tangential or sagittal meridian powers and astigmatic deviation indicated by the automated parameters of the dioptrimeter, were measured at each point. The tangential and sagittal curve variation tendencies were compared to data of the computer software by Darryl J. Meister Spectacle Optics, v2.0 Beta in order to find out whether the measured experimental values of peripheral astigmatism and their interdependencies comply with the ones calculated mathematically and evaluate possibilities of the dioptrimeter in measuring the ophthalmic lenses at other points than their optical centres. Conclusions: The ophthalmic lens characteristics measured at the optical centre using the dioptrimeter nearly coincide with the values indicated on the lens packages. The astigmatic deviations were dot recorded at the centre of the lenses. The findings of the study allowed stating that, when the eye is turned towards a periphery (in 10°), minor changes in the lens power and astigmatism do not affect the vision quality. However, the values of peripheral measurements of the lens power deviations (at the points of 20° and 30°) that is, either increased or decreased power values, of all lenses went beyond the permissible limits (the normal values fall within the range of +/- 0.12D). The peripheral astigmatism was analyzed in all of the measured lenses. Results of the analysis showed that the peripheral astigmatism depends on the lens power directly. The dependence on the refraction index and the base curve was better expressed in the diffusive ophthalmic lenses. The above findings of the study show the substantial compliance of the experimental results and calculated values. Therefore, it can be stated that dioptrimeter can relatively measure and evaluate the usable lens power at the points other than the optical centre of the lens.

Degree

thesis:*
Grantor dc:publisher
Institutional Repository of Vilnius University
Year dc:date
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Baužienė, Angelina,
Contributors dc:contributor
  • Rasa, Žemaičiūnienė
  • Žemaičiūnienė, Rasa

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • info:eu-repo/semantics/openAccess
Language dc:language
lit

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Vilnius University
Base URL
epublications.vu.lt/oai
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Baužienė, Angelina,. Akinių lęšių periferinio astigmatizmo tyrimas /. Institutional Repository of Vilnius University, 2017. https://repository.vu.lt/VU:ELABAETD22675081&prefLang=en_US