Institutional Repository of Vilnius University
Radijo dažnių juostos elektromagnetinės spinduliuotės dinamika Vilniaus mieste /
Abstract
dc:descriptionAim of the study – evaluate radio frequency electromagnetic radiation energy flux density emitted by Vilnius city base stations in the years 2009 – 2012 and compare results with the Republic of Lithuania hygiene standards HN 80:2011 and HN 80:2015 provisions. Study materials and method. In this paper the UAB (Ltd.)”Akustinių tyrimų centras” prepared measurement protocols of radio engineering objects in Vilnius city were used. Data analysis was performed using the statistical package ”R” 3.4.0. In total 214 base station measurement protocols of the years of 2009 – 2012 were collected. Normality of data sets was determined by using Shapiro-Wilks normality test and considered as a normal distribution when the confidence level was p > 0.05. Results. 43 base station measurement protocols were collected in the year of 2009. Base station at Fabijoniškių st. 95 has the maximum value of 3,4 µW/cm^2, which is the biggest of all studied base station measurement values in the year of 2009. An estimated median of all measurement values in the year of 2009 is equal to 0,1 µW/cm^2 (±0,27 SD). 38 base station measurement protocols were collected in the year of 2010. Base station at Fabijoniškių st. 4 has the maximum value of 2,0 µW/cm^2, which is the biggest of all studied base station measurement values in the year of 2010. An estimated median of all measurement values in the year of 2010 is equal 0,1 µW/cm^2 (±0,26 SD). 64 base station measurement protocols were collected in the year of 2011. Base stations at Laisvės ave. 80 and Mindaugo at. 1A has the maximum value of 1,4 µW/cm^2, which is the biggest of all studied base station measurement values in the year of 2011. An estimated median of all measurement values in the year of 2011 is equal 0,1 µW/cm^2 (±0,23 SD). 69 base station measurement protocols were collected in the year of 2012. Base station at Architektų st. 67 has the maximum value of 1,6 µW/cm^2, which is the biggest of all studied base station measurement values in the year of 2012. An estimated median of all measurement values in the year of 2012 is equal 0,1 µW/cm^2 (±0,23 SD). Conclusion. No dynamics detected because of Vilnius city radiofrequency electromagnetic radiation measurement median uniformity (0,1 µW/cm^2) in the years of 2009 – 2012. In defiance of asymmetrical distribution, averages of the years 2009 – 2012 were used. Then dynamics with descending trend is observed. Comparing maximum values of the years of 2009 – 2012 with the Republic of Lithuania hygiene standards HN 80:2011 and HN 80:2015 regulated limit values, no exceedances were found. Mostly, maximum values were recorded in home corridor balconies or staircases and in the living area. A suggestion to validate radiofrequency electromagnetic wave measurements in fifth to twelfth floor apartments and administrative premises is made. Keywords. Vilnius city, base station, radiofrequency electromagnetic radiation.
Degree
thesis:*- Grantor dc:publisher
- Institutional Repository of Vilnius University
- Year dc:date
- 2017
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Staniulytė, Justė,
- Contributors dc:contributor
-
- Vainauskas, Saulius
Rights
dc:rights- Statement dc:rights
-
- info:eu-repo/semantics/openAccess
- Language dc:language
- lit
Identifiers
dc:identifier.*- Repository record dc:identifier
- https://repository.vu.lt/VU:ELABAETD23193581&prefLang=en_US