Institutional Repository of Vilnius University
Didelio diametro pluoštų fokusavimo tyrimas /
Abstract
dc:descriptionResearch on Focusing Large Diameter Beams High intensity laser research is a topic of great interest in modern sciences. These laser sources have various scientific applications. One of the most interesting examples is high-harmonic generation in gases, which requires intensity of a beam to be around 1015W/cm2. To reach such intensity with a laser system, which has energy of 10mJ and generates pulses with duration around 10fs, it is necessary to have beam focused to a spot, smaller than 100µm. Precise focusing requires careful selection of optical elements to be used. Avoiding aberrations is crucial for having high beam quality. That brings to the goal of this work – to measure aberrations, which can be caused by spherical mirrors of large aperture. To begin with, there were theoretical computations performed. It was found, that in ray-trace system both spherical and parabolic mirrors perform the same. Also, it was calculated what angles should be used in beam focusing-expanding system and how these angles would affect final result. Moreover, the difference in focusing expanding and collimated beams was estimated. In experimental part, using He-Ne laser (wavelength λ=632nm) and a telescope, there was made an optical system, generating 20-23mm diameter collimated beam. Specifications of this beam were measured, and it was found that beam experiences slight astigmatism. Furthermore, characteristics of the beam, reflected from 75mm diameter and R=3000mm spherical mirror were measured. It was found, that at angle of incidence equal to 0o, spherical mirror focuses 22mm beam to 60µm spot. Comparing with theoretical calculations, it is just 1.074 times larger. In addition, to avoid initial astigmatism in a system, there was made a system, consisting of one thin lens and a focusing mirror. The system generated 40mm diameter expanding beam. It was found, that focusing at 0° angle with R=2400mm spherical mirror spot sizes would be 57µm, with R=2400mm parabolic - 50µm. If focusing collimated beam with the same parameters, twice as small spot size should be expected. Also, by varying angle of incidence, changes of focus spot size and astigmatism were observed. All measured values were compared with theoretical ones. The change of astigmatism in real system is faster than in theoretical one, but the shape of the slope remains the same.
Degree
thesis:*- Grantor dc:publisher
- Institutional Repository of Vilnius University
- Year dc:date
- 2016
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Jarockytė, Rimantė,
- Contributors dc:contributor
-
- Varanavičius, Arūnas
Rights
dc:rights- Statement dc:rights
-
- info:eu-repo/semantics/openAccess
- Language dc:language
- lit
Identifiers
dc:identifier.*- Repository record dc:identifier
- https://repository.vu.lt/VU:ELABAETD23239276&prefLang=en_US