Institutional Repository of Vilnius University
Inkstų akmenų sparčios kokybinės ir kiekybinės spektrinės analizės sistemos sukūrimas /
Abstract
dc:descriptionDevelopment of System for Rapid Qualitative and Quantitative Spectral Analysis of Urinary Stones It is important to identify the formation causes of urinary stones and prevention means of this disease. Therefore, many different methods are used to analyse human urinary stones. These methods are usually used in laboratories. In order to make the methods less complicated and more suitable to use in routine practice, systems for automatic qualitative and quantitative analysis of urinary stones have to be developed. Fourier transform infrared (FT-IR) spectrometry methods, such as transmission technique or attenuated total reflection (ATR) technique, are popular methods to analyse urinary stones. These are reliable and rapid ways to record IR absorption spectra of materials; the spectra can then be used for qualitative and quantitative spectral analysis. The main aim of this work was to develop a system for rapid qualitative and quantitative spectral analysis of urinary stones. In order to attain the main aim, some tasks had to be performed. Firstly, samples were carefully prepared to record the IR absorption spectra of synthetic materials by transmission and ATR techniques. In order to check the quality of the sample preparation, several samples of the same material were produced and their spectra recorded. In addition, a correlation between intensity of the ATR spectra and the quality of the sample grinding was checked. Furthermore, spectral libraries were created and programs for spectral qualitative and quantitative analysis were produced. Eventually, the programs were tested. During the work the following results were obtained. At first, the recorded spectra were analysed. Secondly, the results of the test of the sample preparation revealed a good quality and reproducibility of the samples for transmission technique (the root-mean-square deviation (RMSD) of integrated spectral bands was equal to 0,6 %) and smaller matching of the ATR spectra (the RMSD of the integrated bands was equal to 22,5 %). Because of low matching of the ATR spectra, no correlation between intensity of the ATR spectra and the quality of the sample grinding was identified. The program of qualitative analysis used the absorption spectra of synthetic materials from the library to identify the spectrum of an unknown urinary stone. It was determined that the program is suitable to analyse single-component kidney stones and to identify major components of multi-component kidney stones. However, the program has still some drawbacks. Similar absorption spectra of different materials are sometimes misidentified. The program of quantitative analysis was tested with IR absorption spectra recorded in transmission mode. It was deduced that this program is able to approximately calculate ratios of components in multi-component kidney stones. During quantitative analysis the average deviation from real percentages was equal to 7,1 % and the maximum deviation was equal to 12,9 %.
Degree
thesis:*- Grantor dc:publisher
- Institutional Repository of Vilnius University
- Year dc:date
- 2016
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Čokovas, Arnoldas,
- Contributors dc:contributor
-
- Pučetaitė, Milda
Rights
dc:rights- Statement dc:rights
-
- info:eu-repo/semantics/openAccess
- Language dc:language
- lit
Identifiers
dc:identifier.*- Repository record dc:identifier
- https://repository.vu.lt/VU:ELABAETD23247178&prefLang=en_US