Back to search

Institutional Repository of Vilnius University

Funkcionalizuotų fermentų panaudojimas biojutiklių konstravime /

Abstract

dc:description

VILNIUS UNIVERSITY FACULTY OF CHEMISTRY AND GEOSCIENCES SIMONAS GRYBAS Application of functionalized enzymes in biosensor construction One of the key goals of modern biosensor engineering is to develop reagentless biosensors that do not require external redox reagents for operation. Such sensors are often based on the interaction between enzymes and electron transfer mediators, allowing enzymes to transfer electrons to the electrode. The aim of this work was to functionalize enzymes with a ferrocene derivative and to create reagentless bienzymatic biosensors by covalently functionalizing enzymes with a ferrocene derivative and adapting them for the detection of sarcosine and hydrogen peroxide. The main subjects of investigation were glucose oxidase (GOX), sarcosine oxidase (SOX), and horseradish peroxidase (HRP), which were modified by attaching N-(ferrocenylmethyl)-6-aminohexanoic acid (Fc-AHA) using a carbodiimide coupling reaction. After synthesis, the specific enzymatic activity of the conjugates was determined and compared to the native enzymes. The synthesized enzyme–mediator conjugates were characterized using spectrophotometric and electrochemical methods, including determining the number of bound mediator molecules and the redox potential. Spectrophotometric analysis showed that an average of 27 ± 8 Fc-AHA molecules were bound per SOX molecule, and 10 ± 1 per HRP molecule. Modification led to a decrease in enzyme activity: SOX activity decreased 6.5-fold, and HRP activity decreased 1.3-fold. Cyclic voltammetry showed that the redox potential of Fc-AHA (E₁/₂ ≈ 0.32 V vs SCE) did not change significantly after conjugation with enzymes, indicating the electrochemical stability of the mediator. The functionalized enzymes were immobilized on graphite electrodes coated with a composite of carbon nanotubes and Nafion polymer to enhance electron transfer and enzyme stability. The biosensor with functionalized glucose oxidase showed a sensitivity of 0.91 µA/mM for glucose at an electrode potential of 0.35 V vs SCE, pH 7.0. The biosensor with functionalized sarcosine oxidase did not show a significant response to sarcosine addition, which is attributed to low enzyme activity after modification. For the construction of bienzymatic electrodes, modified or native SOX and varying amounts of modified HRP were used. Chronoamperometry was used to evaluate the performance of four different bienzymatic sensors in reductive mode (E = 0.2 V vs SCE). The most sensitive biosensor for sarcosine detection was the combination of native SOX and double the amount of HRP, with a sensitivity of Iₘₐₓ/Kₘ = 3.6 µA/mM. For hydrogen peroxide detection, the most effective sensor used modified SOX and increased HRP, with a sensitivity of Iₘₐₓ/Kₘ = 5.0 µA/mM. The results indicate that enzyme modification significantly affects catalytic activity and biosensor sensitivity, but with appropriate enzyme combinations and electrode design, biosensor performance can be maintained or even improved. This study supports the potential of functionalized enzymes in the development of precise, reagentless biosensors.

Degree

thesis:*
Grantor dc:publisher
Institutional Repository of Vilnius University
Year dc:date
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Grybas, Simonas,

Rights

dc:rights
Statement dc:rights
  • info:eu-repo/semantics/openAccess
Language dc:language
lit

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Vilnius University
Base URL
epublications.vu.lt/oai
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Grybas, Simonas,. Funkcionalizuotų fermentų panaudojimas biojutiklių konstravime /. Institutional Repository of Vilnius University, 2025. https://repository.vu.lt/VU:ELABAETD239017727&prefLang=en_US