Institutional Repository of Vilnius University
Vienkartinio kolorimetrinio urėjos biojutiklio kūrimas panaudojant pH indikatorinius dažus /
Abstract
dc:descriptionThe Most Popular Methods for Determining Urea Levels in the Body as of Today Use Inva-sively Obtained Analytes. These sample collection methods can cause discomfort to patients, in-crease the risk of infection, and require specialized personnel training and expensive equipment. The aim of this bachelor’s thesis is to develop a disposable colorimetric urea biosensor that can determine urea concentration from saliva. The objectives of the study are to select a suitable pH indicator dye; to optimize the amounts of urease enzyme and pH indicator dye used; to design and optimize the biosensor’s structure; and to compare the developed biosensor with reliable analytical methods. The reliability of using changes in salivary urea levels to diagnose diseases was evaluated by analyzing literary sources. The research was conducted at the Bioanalysis Department laboratory of the Biochemistry Institute at Vilnius University’s Life Sciences Center in 2025. It was determined that bromothymol blue is a suitable indicator dye for the biosensor. During experiments, the optimal urease enzyme concentration was found to be 0.05 mg/mL, and the optimal pH indicator dye concentration is 0.2 mg/mL. Experiments revealed that due to the viscosity of saliva, it needs to be diluted with a 0.5% TWEEN 20 aqueous solution. Using the “AUTODESK Tinkercad” website, a base with a channel and a cover was designed. After testing several channel diameters, a 3 mm channel was chosen as it allowed the diluted saliva to flow most consistently. A method for manufacturing the sensor was developed, where PCL filament is absorbed by paper from both sides. Spectrophotometric measurements showed that when saliva is diluted using a mechanical pipette, the manufactured biosensor indicates an average of 84.42% lower urea concen-tration in the sample. When saliva is collected and rinsed from cotton swabs, the biosensor shows an average of 28.78% lower urea concentration in the sample compared to measurements obtained with a spectrophotometer.
Degree
thesis:*- Grantor dc:publisher
- Institutional Repository of Vilnius University
- Year dc:date
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Kirkliauskas, Rokas,
Rights
dc:rights- Statement dc:rights
-
- info:eu-repo/semantics/openAccess
- Language dc:language
- lit
Identifiers
dc:identifier.*- Repository record dc:identifier
- https://repository.vu.lt/VU:ELABAETD239024642&prefLang=en_US