Institutional Repository of Vilnius University
Atsparus perkrovoms elektrometrinis stiprintuvas /
Abstract
dc:descriptionRobust Electrometric Amplifier As technology constantly evolves, so does electrometers. There is a need to achieve high sensitivity of this device as it is used in high variety of scientific experiments. To improve sensitivity various amplifiers are used with field effect tranzistors and currently the most popular of them is an operational amplifier with JFET tranzistors. However in modern electrometers with operational amplifiers they have two major flaws: high cost and sensitivity to electrostatic voltage. To develop the sensitivity most modern electrometer operational amplifier is with integrated guard buffer. I used ADA4530-1 type electrometer operational amplifier with is one of the first amplifiers in the world with integrated guard buffer. It is an operational amplifier designed to interface with the extremely high impedance sensors used in electrometer applications. The ADA4530-1 achieves extremely low input bias currents while simultaneously providing robust protection against ESD damage. A unique ESD diode structure provides protection while also allowing the diodes to be guarded to minimize leakage currents to the input pins. In this study the electrometer operational amplifier with integrated guard buffer was studied under various conditions to show device’s capabilities. First the device was tested with various impedance and capacitors to show basic voltage relaxation over time at 21 °C room temperature. Additional results were measured to show how the performance reacts to temperature change at 40 °C and 80°C. The results of these tests show that this specific electrometer is best used at temperature range between 21 and 30°C where output bias current is low and stable. To test capabilities of the guard buffer compared performance of diodes used in my electrometer and a JFET type transistor. The results showed that the JFET type transistor generates dangerously high input voltage at higher (for ex. 1-5kV ESD) input current which is significantly worse than the electrometer with integrated guard buffer. Additional study shows that the integrated guard buffer determines input impedance. It means that if a guard bias voltage is close to zero, then the whole device input impedance is determined only by the leakage of a plastic frame and input transistor. In other cases, as bias voltage of the guard amplifier gets higher, the impedance of an electrometer amplifier input becomes lower. It can be concluded that the electrometer with an ADA4530-1 type operational amplifier is highly resistant to ESD overloads and for this reason it is better than other electrometers with a traditional guard system.
Degree
thesis:*- Grantor dc:publisher
- Institutional Repository of Vilnius University
- Year dc:date
- 2018
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Girštautas, Ramūnas,
- Contributors dc:contributor
-
- Viliūnas, Mindaugas
Rights
dc:rights- Statement dc:rights
-
- info:eu-repo/semantics/openAccess
- Language dc:language
- lit
Identifiers
dc:identifier.*- Repository record dc:identifier
- https://repository.vu.lt/VU:ELABAETD29825208&prefLang=en_US