Back to search

Institutional Repository of Vilnius University

Application of organic functional materials for radiation therapy absorbed dose monitoring /

Abstract

dc:description

In this bachelor’s thesis, organic functional materials intended for X-ray absorbed dose monitoring were investigated. Organic materials are promising for ionizing radiation sensors because their molecular structure can be modified, large-area layers can be formed, and lightweight, potentially flexible devices can be produced. Three similar carbazole-based organic materials were used in this work: K-31.p, K-179.Br, and V-1850.I. The K-31.p molecule contains a simple central phenyl ring, the K-179.Br molecule contains a bromine-functionalized benzene ring, and the V-1850.I molecule contains an iodine-functionalized benzene ring. These materials were mixed with o-carborane, a boron-rich molecule with a three-dimensional cluster structure. The samples were prepared by forming aluminium/organic/aluminium structures. A bottom aluminium electrode was deposited on glass substrates by vacuum evaporation. The samples were then coated with mixtures of different material ratios by drop casting, and the top aluminium electrode was also formed by vacuum evaporation. Mixtures with different ratios were prepared using tetrahydrofuran (THF) or toluene as solvents. The surface morphology of the prepared samples was evaluated using optical microscopy, and the retained sample mass and layer thickness were also measured. Measurements were performed by exposing the samples to X-ray radiation. The dark current and the current under X-ray irradiation were measured. From these data, the photocurrent was calculated. The dependence of photocurrent on applied voltage and X-ray tube current was investigated. The measurements showed that all successfully prepared samples responded to X-ray radiation: the total current increased compared with the dark current, and the photocurrent increased with increasing applied voltage and X-ray tube current. Although stronger responses from K-179.Br and V-1850.I were expected based on photoelectric absorption data, the measurements did not show a clear advantage of these materials over K-31.p. This indicates that the final photocurrent depends not only on X-ray absorption, but also on charge carrier transport, electrode contact quality, layer morphology, thickness, and retained material amount. A clearer trend was observed when changing the o-carborane content: samples containing o-carborane often showed higher photocurrent values, but also became mechanically less stable, more brittle, more aggregated, and lost a larger fraction of their initial mass. In summary, the investigated organic material and o-carborane layers are sensitive to X-ray radiation and can be used as a basis for further research on organic radiation sensors.

Degree

thesis:*
Grantor dc:publisher
Institutional Repository of Vilnius University
Year dc:date
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Česaitis, Deividas,

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • info:eu-repo/semantics/openAccess
Language dc:language
eng

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Vilnius University
Base URL
epublications.vu.lt/oai
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Česaitis, Deividas,. Application of organic functional materials for radiation therapy absorbed dose monitoring /. Institutional Repository of Vilnius University, 2026. https://repository.vu.lt/VU:ELABAETD308116740&prefLang=en_US