Institutional Repository of Vilnius University
Vacuum forming of organic functional layers for biomedical applications /
Abstract
dc:descriptionSummary The aim of this work was to fabricate radiation sensitive organic layers for biomedical applications and evaluate their electrical response under X-ray irradiation. The organic layers were deposited on Corning glass substrates with evaporated aluminum electrodes using thermal vacuum evaporation method. Several organic compounds were investigated, including the hole-transport materials TPD and S-100, and the electron-accepting materials V-1770 and o-carborane. Blended TPD+V-1770 layers were also prepared, including samples in which both organic materials were dissolved in chloroform. Layer thickness was determined from the capacitive response under a linearly increasing voltage, and optical microscopy was used to examine morphology. It was found that the initial evaporation configuration produced thin, poorly formed layers due to elevated substrate temperature, so the setup was modified to reduce the substrate temperature (~50 °C). The measured film thicknesses ranged from 4 to 10 µm. Mechanical stability depended strongly on the material: TPD formed stable films, whereas S-100 layers cracked and delaminated, indicating poorer adhesion and higher sensitivity to internal stress. Polarized optical microscopy revealed birefringent domains in TPD films, suggesting partial crystallization, while the TPD+V-1770 blends exhibited even more pronounced domain structure, showing that blending modifies film solidification. Finally, the fabricated layers were tested under X-ray irradiation to measure I–V characteristics. The highest photocurrent for a 10 µm TPD film was 0.98 nA at 150 V, which is about three times higher than in the 4 µm TPD sample. The calculated charge carrier mobility was 4.32 ×10^(-5) cm2/(Vs) for the 4 µm film and 4.12 ×10^(-5) cm2/(Vs) for the 10 µm film. All samples exhibited an increase in photocurrent under X-ray irradiation, and the intensity-dependent response showed that the blended TPD+V-1770 layers demonstrated the most promising and stable X-ray sensitivity, indicating that these materials and their mixtures are great candidates for future studies.
Degree
thesis:*- Grantor dc:publisher
- Institutional Repository of Vilnius University
- Year dc:date
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Latvaitis, Tomas,
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- info:eu-repo/semantics/openAccess
- Language dc:language
- eng
Identifiers
dc:identifier.*- Repository record dc:identifier
- https://repository.vu.lt/VU:ELABAETD308116831&prefLang=en_US