Automatizuotas didelio dinaminio diapazono spektrometras spektro sričiai nuo 500 iki 3000 nm /
Abstract
dc:descriptionThe rapid development of laser technologies, particularly ultrashort pulse and broadband laser sources, has created a growing need for spectroscopic instruments capable of covering wide spectral ranges with sufficient resolution and sensitivity. Conventional solutions often require multiple devices or frequent component changes, which increase measurement time. To address this, this bachelor’s thesis aimed to construct and characterize a single-prism spectrograph covering a broad continuous spectral range from 500 nm to 3000 nm, testing two different prism materials - YAG and SF10 - and to compare their performance. For YAG and SF10, wavelength-dependent refractive indices, angular deviation, spatial separation on the detector plane, and theoretical resolving power 𝑅 = 𝜆 ∆𝜆 were calculated. The optical design was based on single-pass mirror monochromator configuration utilizing two concave mirrors (f = 30cm), a flat mirror mounted on a motorized rotation stage together with the prism and adjustable entry and exit slits. A thermal white-light source was used together with bandpass filters for wavelength calibration. Measurements were performed in two parts - with a Si photodiode detector (400–1000 nm) and a ThorLabs-PDA30G PbS detector (1000–3000 nm). Intensity dependence on rotation angle was recorded for both prisms using differing wavelength filters, which then allowed to calculate approximate formulas for rotation angle to wavelength conversion, which in turn gave the resolution values at different wavelengths. The constructed spectrograph covered the full 500–3000 nm range. Experimental resolving power was significantly lower than theoretical predictions, likely due to slit width (an assumption that a point light source was used), and possibly optical aberrations, yet followed the expected wavelength dependence. SF10 showed slightly better performance in the visible and near-IR region, while YAG performed marginally better at longer wavelengths (>2.5µm). Acceptable signalto-noise ratios were achieved, especially in the infrared with the PbS detector. Thus, a relatively simple single-prism system can provide continuous, single order, and thus order overlap-free, spectral coverage across a wide range, making it suitable for basic laser diagnostics and educational applications.
Degree
thesis:*- Grantor dc:publisher
- Institutional Repository of Vilnius University
- Year dc:date
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Malakauskas, Martynas Povilas,
Rights
dc:rights- Statement dc:rights
-
- info:eu-repo/semantics/openAccess
- Language dc:language
- lit
Identifiers
dc:identifier.*- Repository record dc:identifier
- https://repository.vu.lt/VU:ELABAETD308117823&prefLang=en_US