Institutional Repository of Vilnius University
Dalelės judėjimo valdymas mikrofluidiniame kanalėlyje /
Abstract
dc:descriptionMicrofluidic systems allow precise control of small liquid volumes, flow conditions and the microenvironment of biological object. In this work, hydrodinamic manipulation was chosen because it enables object motion to be controlled by liquid flow and microchannel geometry without additional electric, optical or magnetic fields. The aim of this work was to develop and test a microfluidic system prototype for controlling the motion of an phantom, mimicking a cell organoid. The system consisted of custom-built syring pump, a scaled-up microfluidic chip with a trapping region, agar phantoms and a camera-base image analysis program. The syring pumps showed a linear relationship between motor steps and displaced liquid volume, with a coefficient of determination of 0.999. However, backlash limited the dosing accuracy and depended on the motion direction: 239±17 steps in the withdrawal direction and 100±3 steps in the pushing direction. Computational fluid dynamics simulation showed that the selected trap geometry formed a lower velocity region that directed the particle into the trap. Reynolds number estimates confirmed laminar flow in both the small scale model, where R_e=0.5 and the scaled up prototype where R_e=6.7. Agar phantoms were produced as scaled up organoid substitutes, their size depended on the stirring speed: 444 rpm produced 2-4 mm phantoms, while 66 rpm produced smaller phantoms suitable for channel testing. Experimental test showed that trapping depended on the main flow rate: 100% trapping was achieved at 0.01 ml/s while the trapping propability decreased to 70% at 0.0106 ml/s and 20% at 0.0122 ml/s. The object could also be released using the lower inlet flow with release efficiency increasing from 40% at 0.0099 ml/s to 100% at 0.0366 ml/s. A camera-based image analysis algorithm was used to detect object rotation by comparing the initial and current region of interest. A full rotation was detected when the similarity coefficient exceeded 86% for several consecutive frames. The developed prototype can be used for further optimization of hydrodynamic trapping, releaseand motion monitoring of organoid.
Degree
thesis:*- Grantor dc:publisher
- Institutional Repository of Vilnius University
- Year dc:date
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Peleckis, Mykolas,
Rights
dc:rights- Statement dc:rights
-
- info:eu-repo/semantics/openAccess
- Language dc:language
- lit
Identifiers
dc:identifier.*- Repository record dc:identifier
- https://repository.vu.lt/VU:ELABAETD308118503&prefLang=en_US