Institutional Repository of Vilnius University
Double channel pumping for filament assisted x-ray generation /
Abstract
dc:descriptionThe study of laser-induced plasma X-rays are of particular interest due to their possibility as alternative X-ray sources to vacuum tubes, which dominate the market. These sources show potential with favorable qualities of customizability and great spatial and temporal resolution, however they have struggled to achieve widespread applications due to stability and other issues. This work aims to investigate and optimize a filament propagation assisted laser induced plasma X-ray source with a temporally delayed two channel pumping configuration. In this study, a one channel system was initially used to investigate the evolution of X-ray photon flux over runs of 5-15 minutes during which a contour on a rotating sample was continually irradiated with laser pulses. The profile of the sample was investigated with a profilometer at different points in the run and compared to the measured X-ray generation. The maximum photon flux of these runs was used to investigate the efficiency dependence on different parameters: pulse duration and position of the sample. Focal distance measurements were carried out with an optical telescope to optimize the focusing conditions. Finally two channel measurements were performed by splitting the incident beam into two components with varying power distributions between them and a temporal delay of ~500 ps achieved through a delay line. Experimental results of profile measurements showed that during irradiation microstructures started to form on the surface of the sample. Their formation coincided with an increase in X-ray generation by a factor of ~1000, this is believed to be caused by the local field enhancement effect. Pulse duration measurements have shown that the highest efficiency is achieved at a duration of ~200 fs. Focal distance measurements showed that the best generation is achieved with a 200 cm focal distance. In the two channel configuration the best power proportion between the beams was found to be around 50%/50% and it displayed X-ray generation better than sum of the individual channels, a high initial flux and the extension of efficient generation from ~10 minutes to 2,5 hours.
Degree
thesis:*- Grantor dc:publisher
- Institutional Repository of Vilnius University
- Year dc:date
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Logminas, Šarūnas,
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- info:eu-repo/semantics/openAccess
- Language dc:language
- eng
Identifiers
dc:identifier.*- Repository record dc:identifier
- https://repository.vu.lt/VU:ELABAETD308118660&prefLang=en_US