Institutional Repository of Vilnius University
Akinių pergaminimo atvejų analizė optometrininko praktikoje /
Abstract
dc:descriptionVision correction accuracy is important for ensuring optimal visual function and patient comfort, while inaccuracies may lead to the need for spectacle remakes. The aim of the study was to evaluate cases of spectacle remakes in optometric practice and to identify the main causes leading to the occurrence of remakes. Objectives of the study: 1. To evaluate the characteristics of spectacle remake cases based on the internal data of an optical company. 2. To determine the most common types and causes of spectacle remake cases. 3. To identify the stages of the optical correction fitting process in which inaccuracies most commonly occur. The study analysed 435 cases of spectacle remakes registered in the internal electronic system of an optical company during the period of 2023– 2024. A retrospective qualitative study was conducted using the document analysis method to determine the main causes of spectacle remakes and their distribution. The results of the study showed that the majority of spectacle remake cases were related to inaccuracies in vision correction selection. The most frequently identified issues were inaccuracies in cylindrical correction (23 perc.), under correction (22.5 perc.), and overcorrection (21.6 perc.), as well as general refractive inaccuracies (16.1 perc.), which included cases where changes in correction were complex, and intolerance could not be associated with a specific refractive component. A smaller proportion of cases was related to lens design selection, communication, and administrative factors. It was found that even minor changes in correction may have a significant impact on visual comfort and spectacle tolerance. The study also revealed that some cases were associated with the interaction of multiple factors, including individual visual characteristics of the patient, adaptation processes, and communication aspects. The conclusions indicate that the causes of spectacle remakes are multifactorial, and that reducing the number of such cases requires accurate refraction assessment, comprehensive evaluation of patient needs, and high-quality information transfer throughout the entire process.
Degree
thesis:*- Grantor dc:publisher
- Institutional Repository of Vilnius University
- Year dc:date
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Bareikienė, Kornelija,
Rights
dc:rights- Statement dc:rights
-
- info:eu-repo/semantics/openAccess
- Language dc:language
- lit
Identifiers
dc:identifier.*- Repository record dc:identifier
- https://repository.vu.lt/VU:ELABAETD308319845&prefLang=en_US