Back to search

Institutional Repository of Vilnius University

Transgeninių elementų paieškos sistemos parinkimas ir metodo optimizavimas naujų GM sojos linijų kontrolei /

Abstract

dc:description

Selection of Screening Systems for Transgenic Elements and Method Optimisation to Detect New GM Soy Events The aim of this study is to develop and optimise screening systems to detect new GM soy events. After examination of 37 routine samples received in 2016-2017 by National Food and Veterinary Risk Assesment Institute of Lithuania that were evaluated as positive while testing for GM soy events GTS-40-3-2 ir A2704-12 in 23 of them seven new GM soy events were detected. Methods to detect these events are not currenttly validated in NFVRAI. Thirteen standart DNA calibration curves were set up for new GM soy events using DNA extracted from certified reference materials. Parameters of standard DNA calibration curves meet the requirements and fall into required range. This confirms the suitability of standart curves to use in further method development. The standard calibration curves of seven GM soy events that were detected in routine samples were used to determine limits of detection and limits of quantification for these events. Limits of detection for all seven events meet the method requirements and allows to detect transgenic elements with 95% confidence when there are 10 and more copies of the transgenic element in the sample. After determining relative reproducibility standard deviation limits of quantification were determined. Limits of quantification meet the requirements for the method and allows to detect and quantify transgenic elements when there is 40 copies and more for the events MON87701, MON87708, MON87769 ir FG72 and 20 copies and more for the events MON89788, A5547-127 ir DP305423. Three multiplex PCR systems that cover the detection of six GM soy events that do not have usual screening elements and one event that was the most common in routine samples were developed. Determined limits of detection shows that multiplex systems are able to detect transgenic elements with 95% confidence whem there are 10 and more copies. Amount of transgenic elements in rotine samples was determined after quantitative analysis.

Degree

thesis:*
Grantor dc:publisher
Institutional Repository of Vilnius University
Year dc:date
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Lenkaitė, Ieva,
Contributors dc:contributor
  • Jurgelevičius, Vaclovas

Rights

dc:rights
Statement dc:rights
  • info:eu-repo/semantics/openAccess
Language dc:language
lit

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Vilnius University
Base URL
epublications.vu.lt/oai
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Lenkaitė, Ieva,. Transgeninių elementų paieškos sistemos parinkimas ir metodo optimizavimas naujų GM sojos linijų kontrolei /. Institutional Repository of Vilnius University, 2018. https://repository.vu.lt/VU:ELABAETD35780640&prefLang=en_US