Virginia Polytechnic Institute
Shielding calculations for the VPI UTR-10 reactor at 10kw
Abstract
dc:description.abstractA re-evaluation of the radiation shield of the V. P. I. UTR-10 nuclear reactor is necessary before an. increase in the licensed reactor power from 10 kw to 100 kw can be accomplished. Experimental measurements at 10 kw indicated satisfactory performance of the shield for neutrons but certain regions have a higher gamma dose rate than had been predicted by the original shield design. The results of the experimental measurements were used to establish a gamma ray source distribution. This distribution was then used to calculate the gamma dose rates at various positions around the reactor after an addition of a lead gamma shield on two sides of the reactor core. The results indicated that additional shielding may be required on the top of the reactor and on the thermal column closure but the radiation level should not prohibit the increase in the reactor power level.
Degree
thesis:*- Name thesis:degree_name
- M.S
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Nuclear Science and Engineering
- Department dc:contributor.department
- Nuclear Science and Engineering
- Grantor dc:publisher
- Virginia Polytechnic Institute
- Year dc:date.issued
- 1964
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Andrews, James Barclay
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- In Copyright
- Licence dc:rights.uri
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/10919/138569