The electrical resistances of healthy and Heterobasidion annosus (Fr.) Bref. infected lob lolly pines (Pin us taeda L.) on both low and high hazard sites for annosus root rot were measured. A portable ohmeter called a Shigometer was used for the measurements of the woody tissue. The root systems of the trees were excavated by a bulldozer and measured for length and percent infection. No correlation between root rot infection and electrical resistance was found in the field. However, correlations between root length and tree diameter were highly significant and these correlations were greater on the high hazard site. Loblolly pine trees in six greenhouse plots were also measured for resistance. Three plots were located on a high hazard and three on a low hazard site. Trees in two plots on each site were inoculated with H. annosus by either spore percolation or direct inoculation of one root per tree. The resistance measurements were higher as the potential for infection increased. Trees on the low hazard site had significantly lower resistances than those on the high hazard site. The direct inoculation plots had higher resistances than the control plots. The highest resistances occurred on the spore percolation plots. Two probes differing in electrode spacing (1 cm and 3 cm) were also compared. The 3 cm probe resulted in significantly higher resistance measurements than the 1 cm probe. Electrical resistance was found to be an indicator of tree vigor. As vigor decreased the electrical resistance of the woody tissue increased. The greenhouse study suggests a correlation between electrical resistance and H. annosus root rot infection.

Degree

thesis:*
Name thesis:degree_name
M.S.
Level thesis:degree_level
Major paper
Discipline thesis:degree_discipline
Plant Pathology
Department dc:contributor.department
Plant Pathology
Grantor dc:publisher
Virginia Polytechnic Institute and State University
Year dc:date.issued
1977

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Bardinelli, Ted Robert
Chair dc:contributor.committeechair
  • Alexander, S. A.
Committee members dc:contributor.committeemember
  • Skelly, J. M.
  • Skutt, H. R.

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10919/141346

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Bardinelli, Ted Robert. Comparison of electrical resistances of loblolly pines naturally and artificially infected with Heterobasidion annosus (Fr.) Bref. and healthy loblolly pines to a pulsed electric current. Major paper thesis, Virginia Polytechnic Institute and State University, 1977. https://hdl.handle.net/10919/141346