Virginia Tech
Optimizing Biological Activated Carbon Performance for Chemical Peaking in Potable Reuse
Abstract
dc:description.abstractWater treatment plants employing membrane filtration (MF) coupled with reverse osmosis (RO) and an advanced oxidation process (AOP) are susceptible to the poor rejection of uncharged low molecular weight (LMW) compounds such as formaldehyde and acetone due to the nature of their removal mechanisms. N-nitrosodimethylamine (NDMA) is a LMW organic well attenuated through AOP, however poorly rejected across RO and is therefore also a compound of interest. Although acetone itself is not a significant health concern, instances of high episodic acetone spikes showing up in RO feed and permeate underscores the importance of additional treatment barriers to protect against chemical peaks. These LMW organic compounds, however, are generally well attenuated through established biological filtration. Ozone-biologically activated carbon (O3-BAC) would provide an additional treatment barrier against LMW organics in potable reuse and has promise for protecting against episodic chemical peaks. Literature evaluating BAC performance during chemical spike events of LMW organics, such as formaldehyde, acetone, and NDMA, showed inconsistent findings on removal percentages at similar concentrations. Factors potentially affecting removal between plants include native microbial communities (driven by background organic chemical concentration and nutrient loading onto the filters), dissolved oxygen (DO) concentrations, elevated LMW organic concentrations, and varying O3:TOC doses. Methanol was the relevant organic compound used for chemical challenge testing due to its oxidation to formaldehyde across ozone and supplementation at upstream WWTPs as an external carbon source for denitrification. A series of methanol challenge tests were conducted at a 1 MGD carbon-based advanced treatment indirect potable reuse facility. BAC maintained bulk NDMA (>1-log) and TOC (20-30%) removal as well as maintaining good acetone attenuation (>1-log) during baseline formaldehyde (161±43 ug/L) and peak formaldehyde concentrations (1721±736 ug/L), across a range of temperatures (14.3-27.3° C), and influent ammonia concentrations (<0.02-10 mg/L-N). BAC was hypothesized to achieve 1-log formaldehyde removal during formaldehyde peaks at concentrations ~1,700 ug/L however filters were only able to achieve an average of 81±13% removal. Elevated formaldehyde and ammonia concentrations were hypothesized to negatively impact filter removal of NDMA and acetone however BAC maintained 1-log removal of both constituents under all testing conditions. Unexpected disruptions of NDMA and acetone removal were observed surrounding periods of pre-oxidation upstream O3-BAC. Inconsistent sodium bisulfite feed, used to quench residual chlorine upstream BAC, is thought to be responsible during periods of disrupted removal. Propane amended BAC filters, used for the co-metabolic removal of 1,4-dioxane (a typically biologically recalcitrant compound), demonstrated improved NDMA and acetone removal compared to non-propane amended filters even when not being fed propane.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Civil Engineering
- Department dc:contributor.department
- Civil and Environmental Engineering
- Grantor dc:publisher
- Virginia Tech
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Millspaugh, Madison Elizabeth
- Chair dc:contributor.committeechair
-
- Furst, Kirin Emlet
- Committee members dc:contributor.committeemember
-
- Bott, Charles B.
- Pruden-Bagchi, Amy Jill
Subjects
dc:subject × 7Rights
dc:rights- Statement dc:rights
-
- In Copyright
- Licence dc:rights.uri
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Dc Identifier Other
- vt_gsexam:46765