dc:description.abstractData center processors and xPUs are moving toward higher current and lower supply voltage, making the 48V point-of-load (PoL) voltage regulator increasingly important. Although the 48V bus reduces distribution loss, direct 48V-to-1V conversion remains challenging because the converter must simultaneously achieve a high step-down ratio, high output current, high efficiency, and compact layout. Existing two-stage solutions can reuse mature 12V multiphase buck technology, but the cascaded power conversion, intermediate bus current, and additional decoupling capacitors limit further improvement in efficiency and power density. Therefore, this thesis investigates a single-stage 48V voltage regulator based on a merged half-bridge converter with current-doubler rectification (MHB-CDR). The proposed topology reduces the effective primary side voltage applied to the transformer by merging two asymmetrical half-bridge cells, allowing a practical transformer turns ratio for 48V-to-1V conversion. The current-doubler rectifier (CDR) splits the large output current into two interleaved current paths and reducing secondary side current stress. To realize the proposed topology in hardware, a printed circuit board (PCB) transformer is designed and optimized. Core loss, winding loss, PCB layout and device loss are evaluated. Since core loss is not the dominant limitation in the present design, the transformer optimization focuses on winding resistance and PCB implementation. Different magnetic core design and PCB winding arrangements are compared to reduce total power stage loss. Finally, hardware prototypes are built and tested to verify the proposed design. The proposed converter achieves a measured peak efficiency of 90.48% for 48V-to-1V conversion. Efficiency at different switching frequencies and input-output conditions are also analyzed. Comparative prototypes, including an asymmetric half-bridge converter and a stacked half-bridge converter, are also evaluated to demonstrate the advantages of the proposed MHB-CDR. The results show that the proposed topology achieves higher efficiency under heavy-load conditions, making it a promising single-stage solution for high-conversion-ratio, high-output-current 48V point-of-load applications.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Electrical Engineering
- Department dc:contributor.department
- Electrical Engineering
- Grantor dc:publisher
- Virginia Tech
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Yang, Kaisen
- Chair dc:contributor.committeechair
-
- Li, Qiang
- Committee members dc:contributor.committeemember
-
- Dimarino, Christina Marie
- Zhu, Liyan
Subjects
dc:subject × 3Rights
dc:rights- Statement dc:rights
-
- In Copyright
- Licence dc:rights.uri
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Dc Identifier Other
- vt_gsexam:46660