Virginia Tech
Predicting Heat Accumulation and Layer Geometry Variation in Continuous DED-Arc of Thin-Walled Aluminum Structures
Abstract
dc:description.abstractCompared to other metal additive manufacturing (AM) processes, wire-arc directed energy deposition-arc (DED-Arc) offers high deposition rates. However, its throughput is limited by heat accumulation within the part during the build; continuous printing without balanced heat dissipation can lead to part slumping and distortion. Existing thermal mitigation approaches, including interlayer dwell time, active cooling, and in-process parameter control, impose costs in productivity, system complexity, and/or limited applicability to large and complex parts. Continuous deposition without arc interruption eliminates dwell time and arc start and stop defects but produces a severe heat accumulation condition. Under fixed process parameters, the thermal balance determining this accumulation is strongly influenced by the part's geometry. In a closed contour geometry, the layer contour length of the profile determines the toolpath length, setting the time available for heat to dissipate between depositions of successive layers, while also determining wall surface area. Longer layer contours have been observed to reduce heat accumulation in previous research, but the relationship has not been directly investigated as a design variable in DED-Arc, nor has it been established whether interlayer temperature reaches a plateau at sufficient contour length and/or part height. The aim of this thesis is to establish a design-stage workflow that relates continuous build geometry to its in-process thermal condition and deposited wall geometry, thus allowing layer-wise prediction of part geometry before fabrication. To close this research gap, three thin-walled ER5556 aluminum cylinders of 50, 100, and 200 mm diameter were deposited continuously under identical process parameters and instrumented with embedded thermocouples along the build height. Contour length variation produced a 212.1 °C spread in interlayer temperature across builds and dictated whether steady-state interlayer temperatures could be reached. Calibrated thermal simulation indicated that the interlayer temperature of 200mm diameter cylinder reached a plateau during processing and declined as convective loss exceeded layer-wise heat input. However, the 50mm diameter contour part's interlayer temperature climbed to 401 °C by layer 50 with no sign of stabilizing. This thermal variation increased effective wall width by 99.4% along the part height, whereas porosity and microhardness remained consistent for this alloy. The calibrated simulation was applied to a test geometry and, combined with the measured temperature-geometry correlations, predicted effective wall width and layer height to 3.28% and 2.26% mean absolute percentage error, respectively, across 10 layers sampled from a 50-layer build. The study was also extended to oscillating weave deposition for producing thicker wall widths. Interlayer temperatures in the weave builds were up to 60.4 °C lower than single-track at matched contour length, despite depositing 2.8 times the path length per layer. This longer layer time increased heat dissipation, more than offsetting the higher heat input.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Mechanical Engineering
- Department dc:contributor.department
- Mechanical Engineering
- Grantor dc:publisher
- Virginia Tech
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Rosenhein, Drew David
- Chair dc:contributor.committeechair
-
- Williams, Christopher Bryant
- Committee members dc:contributor.committeemember
-
- Raeymaekers, Bart
- Rao, Prahalada Krishna
Subjects
dc:subject × 5Rights
dc:rights- Statement dc:rights
-
- In Copyright
- Licence dc:rights.uri
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Dc Identifier Other
- vt_gsexam:47894