Back to search

University of Washington

A RC Slab to CFT Column Connection for Improved Seismic Behavior of Multi-Story Buildings

Abstract

dc:description.abstract

Slab-column systems are commonly used as the gravity system of reinforced concrete buildings in high seismic regions. These systems are economical and typically constructed using stud rails at the reinforcement for the slab-column connection. However, prior work indicates that these connections are susceptible to damage and may lose load-carrying capacity at drift demands between 2% and 4%. A research program was undertaken to investigate a new slab-column system which: (i) is economical, (ii) mitigates damage and (iii) can sustain large drifts without loss in strength. The system is novel in that it uses concrete filled steel tubes (CFSTs) as the columns; prior work has demonstrated that these components are ductile, with high flexural, axial and shear capacities. In addition, the tube eliminates the need for longitudinal and transverse internal reinforcement as well as column formwork, thereby reducing construction time. The connection replaces a traditional drop panel with sandwiched steel rings. The rings are connected to the slab with post-tensioned bolts, eliminating the need for stud-rail reinforcement. The steel tubes are prefabricated with the rings and the lower column has longitudinal reinforcement welded to it; this is the only reinforcement in the column and extends through the slab reinforcement into the upper tube of the upper CFST column. This longitudinal reinforcement facilitates load transfer as does the ring-bolt connection assembly. This new connection was investigated experimentally using full-scale tests. Four specimens were tested with the primary study parameters as follows: (i) ring dimension, (ii) bolt pattern. The results indicate that the connection can sustain 6% drift with minimal damage.

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Yeutter, Alec
Advisors dc:contributor.advisor
  • Lehman, Dawn E
  • Roeder, Charles W

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • CC BY-ND
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1773/45464

Chain of custody

source
Harvested from
University of Washington
Base URL
digital.lib.washington.edu/server/oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Yeutter, Alec. A RC Slab to CFT Column Connection for Improved Seismic Behavior of Multi-Story Buildings. 2020. http://hdl.handle.net/1773/45464