Back to search

University of Washington

Assessment and Reduction of Microbial Risks in Emergency Eyewash Stations

Abstract

dc:description.abstract

This pilot study investigates the impact of regular and irregular flushing routines on microbial contamination in eyewash stations across a university, sampling a total of 70 eyewash stations. The primary objective was to assess whether regular flushing effectively reduces the risk of exposure to microbial contaminants, including Heterotrophic Plate Counts (HPC), Legionella pneumophila, and non-tuberculosis Mycobacterium. The results indicate that irregularly flushed eyewash stations showed a higher rate of unsafe microbial counts compared to those with regular flushing and maintenance at 99% confidence interval. Legionella was detected in a single building with irregular flushing, emphasizing the risk of such neglect. This study highlights the critical need for rigorous maintenance routines to ensure the safety and functionality of emergency eyewash stations. The findings advocate for regular flushing as a simple yet effective method to minimize potential health risks, reinforcing the importance of adherence to established safety standards in workplace environments. This pilot study lays the groundwork for future research, suggesting further investigation into the specific conditions that influence microbial presence and the development of maintenance strategies for varying conditions.

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Assaad, Mariam
Advisor dc:contributor.advisor
  • Meschke, Scott

Subjects

dc:subject × 9

Rights

dc:rights
Statement dc:rights
  • none
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1773/51978

Chain of custody

source
Harvested from
University of Washington
Base URL
digital.lib.washington.edu/server/oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Assaad, Mariam. Assessment and Reduction of Microbial Risks in Emergency Eyewash Stations. 2024. https://hdl.handle.net/1773/51978