Back to search

University of Waterloo

Design and Optimization of a Stacked Three-Layer X-ray Detector for Multi-Spectral Medical Imaging Applications

Abstract

dc:description.abstract

Dual-Energy (DE) imaging is a powerful technique in x-ray imaging that increases the ability to detect specific materials in a cluttered background, and is used to more accurately visualize anatomical features and diagnose abnormalities. Single-shot imaging has arisen as one of the dominant techniques used to obtain DE images, but has the intrinsic drawback of a loss of x-ray photons in a metal mid-filter. I propose a new design of a stacked three-layer x-ray detector for DE single-shot imaging that addresses this fundamental drawback. Each layer consists of its own scintillator of individual thickness and an underlying thin-film-transistor-based flat-panel. Three images are obtained simultaneously in the detector during the same x-ray exposure, and thus the imaging system is immune to motion artifacts. The detector operation is two-fold: a conventional radiography image can be obtained by combining all three layers' images, while a DE subtraction image can be captured from the front and back layers, where the middle layer acts as a filter that helps achieve spectral separation. Two sample imaging tasks that can particularly benefit from this new detector design are selected. These are iodinated vessel visualization in coronary angiography and calcified nodule detection in pulmonary radiology. I proceed to optimize the detector parameters and imaging system configuration to best fit these two tasks by obtaining the best possible contrast to noise ratio per root entrance exposure. To achieve this, I develop an analytical model by adapting well-established theoretical foundations to fit this new detector design. These results are compared to a conventional DE temporal subtraction detector and a typical single-shot DE subtraction detector with a metal mid-filter, both of which underwent a similar analytical optimization process. The findings are then validated using advanced Monte Carlo simulations for all optimized detector configurations. The analytical and simulation results indicate that the proposed detector performs comparably as a DE imager to established single-shot detectors. It is therefore clear that this new design is an improvement on the state-of-the-art since it provides an additional feature at no performance cost. Given the performance expected from these initial results and the recent decrease in price for digital x-ray detectors, the simplicity of the three-layer stacked imager approach appears promising to usher in a new generation of multi-spectral digital x-ray imaging.

Degree

thesis:*
Grantor dc:publisher
University of Waterloo
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Lopez Maurino, Sebastian
Advisor dc:contributor.advisor
  • Karim, Karim

Subjects

dc:subject × 8

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/10012/10551

Chain of custody

source
Harvested from
University of Waterloo
Base URL
dspacemainprd01.lib.uwaterloo.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Lopez Maurino, Sebastian. Design and Optimization of a Stacked Three-Layer X-ray Detector for Multi-Spectral Medical Imaging Applications. University of Waterloo, 2016. http://hdl.handle.net/10012/10551