Back to search

Wake Forest University

Surgical Robotic Research Platform for Improved Clinical Translation and Quantifying Forces During Robotic Surgery

Abstract

dc:description.abstract

The use of minimally invasive surgical robotic systems has seen continuous growth since the first FDA approval of the da Vinci Surgical System in 2000. Not only has there been a conversion from open and laparoscopic to a robotic approach, but the improved vision and tool dexterity from robotic systems have enabled new surgical techniques to be performed. Surgical robotic systems are particularly exciting in their ability to be a platform for numerous high-tech health innovations. Numerous academic labs are researching how machine learning, artificial intelligence, augmented reality, and autonomous tasks can be utilized with these systems. While many of these investigations have promising results on a benchtop, the translation to the clinical setting is challenging. To make the transition into the operating room, research must be validated clinically representative models. Currently, most of the research is performed on surrogate synthetic models or animal tissue. While serving as a proof of concept, the surgical robotic environment is complex and still highly understudied. Looking at the current open available data it is limited to video only or tasks being performed on surgeon training tasks. To address this gap in knowledge of detailed and biofidelic surgical data, we evaluated a surgical robotic research platform’s ability to perform cadaveric surgery. Furthermore, we installed a force sensing system to a mega needle driver to quantify the forces at the tip of the tool. We performed a total of five hernia repairs on two different cadavers. These repairs were performed by a total of three surgeons of varying experience levels. After several adjustments to the configuration of the research platform, we found that it was feasible to perform teleoperated minimally invasive surgeries. The force sensing system was able to be utilized without disruption to the procedure and provided the estimated tool tip force synchronized with the video and detailed robot data. From an analysis of the data, we found that forces in the 20 N are commonly applied directly while grasping the body of sutures. Also, the tensioning of the leading suture is where the highest forces are typically reached during a wound closure procedure. We anticipate that continued use of this research platform will be able to provide a meaningful impact on closing the clinical translation gap. By providing openly available data and testing surgical robotic research on more clinically translatable models, the feasibility and critical needs of this growing field can be better identified.

Degree

thesis:*
Discipline thesis:degree_discipline
Biomedical Engineering
Grantor dc:publisher
Wake Forest University
Year dc:date.issued
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Chung, Scotty

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://wakespace.lib.wfu.edu/handle/10339/101762

Chain of custody

source
Harvested from
Wake Forest University
Base URL
wakespace.lib.wfu.edu/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Chung, Scotty. Surgical Robotic Research Platform for Improved Clinical Translation and Quantifying Forces During Robotic Surgery. Wake Forest University, 2023. https://wakespace.lib.wfu.edu/handle/10339/101762