Wake Forest University
EVALUATION OF ANKLE BEHAVIOR TO INFORM FOOTWEAR ANKLE-SUPPORT TESTING METRICS
Abstract
dc:description.abstractAcute musculoskeletal injuries are a prevalent issue within the United States military and cadet populations. During the on-going and rigorous physical fitness training programs required for US military personnel, overuse injuries and lateral ankle sprains are the most frequent acute injuries accounting for 31% and 73.6% of injuries, respectively. Army combat boot design could impact these injuries; however, no ankle-stability metric currently exists for military footwear assessment. Examining footwear ankle-stability in a laboratory setting will require a surrogate model with representative foot-ankle response and anatomy similar to the human leg. With this surrogate model, an objective, repeatable measure of the interface between the foot-ankle complex and issued footwear can be investigated. This novel testing methodology will provide quantitative metrics that address the goal of understanding the boot-to-ankle interface and the influence of boot design on lower limb micro-traumatic musculoskeletal injuries. The following studies propose an appropriate foot-ankle surrogate to be used in the novel footwear testing methodology. The ankle behavior in 53 healthy, adultvolunteers was quantified during gait at 1 m/s. The responses of existing anthropomorphic test devices (ATDs) during gait at 1 m/s were compared to the volunteer data to determine if these models are appropriate surrogates for testing footwear. The ATD responses were found to be statistically different from the human data. The volunteer data was used to design of a custom foot-ankle surrogate and to create an initial biomechanical response target (BRT). This initial BRT evaluates surrogate behavior during gait at 1 m/s. Statistical parametric mapping and visual analyses were the initial techniques used to compare the foot-ankle surrogate to human behavior. These preliminary results were successful and informative to future directions of establishing an ankle-stability metric for footwear testing methodology.
Degree
thesis:*- Discipline thesis:degree_discipline
- Biomedical Engineering
- Grantor dc:publisher
- Wake Forest University
- Year dc:date.issued
- 2023
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Polich, Julia Grace
Subjects
dc:subject × 6Rights
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Repository record dc:identifier.uri
- https://wakespace.lib.wfu.edu/handle/10339/102629