Back to search

University of York

Development of Novel Scintillation Detection Techniques for Use in Nuclear Physics and Medical Applications

Abstract

dc:description.abstract

This thesis describes the practical application of scintillation detector techniques and focuses on how to enhance their potential for use in the new concept spectroscopy method called HELIOS, combination of the magnetic resonance image (MRI) and positron emission tomography (PET) called PET-MRI system, and other medical applications. Optically coupled LaBr3(Ce) with Hamamatsu avalanche photomultiplier first tested inside a (nearly) 1T magnetic field, resulting in the field does not have an adverse impact on the performance of the detector. A magnetic resonance image was also successfully obtained when a scintillation detector system interfaced with a homogeneous magnetic field inside the brain phantom, but detector current influenced on the MR image. In Chapter 2, there are the further investigations into various scintillation detector systems such as Phoswich-PMT, CsI and LYSO coupled with SensL position sensitive SiPM. SensL new-generation blue sensitive B and C series SiPMs have an innovative silicon photomultiplier structure resulting in an additional readout signal for fast timing application. SensL SiPMs with the large photosensitive area studied regarding their characteristics and coincidence time measurement. According to the measurement result, the dependencies of bias voltage, temperature, gain and dark current were consistent with the literature. Coincidence time resolution was gradually improved from 512 ps to 276 ps for 6 mm C-SiPM by changing set-up and adding transformer in the circuit. A novel antimatter detector system developed for medical applications. GEANT4 based GATE 7.0 simulation was used for optimum scintillator thickness investigation to measure the activity directly from positrons rather than gamma radiation without any interference between scintillator and radiopharmacy. Various detector designs successfully tested for microfluidic chip and blood counter applications (measured volume from 94μ to 0.11μ ). The half-life of 68 Ga was experimentally calculated to be 62.11±8 minutes resulting in agreement with the literature if they overlap within their uncertainties. The new detector is cost-effective, based on very simple working principle, user-friendly, easy to modify into another system, and achievable nanoscale volume. Therefore, the objective of this research is to aid significantly in deciding a final design for the detector system before serial manufacturing and before applying for the patent.

Degree

thesis:*
Name dc:type.qualificationname
Ph.D
Level dc:type.qualificationlevel
doctoral
Grantor dc:publisher.institution
University of York
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Yavuzkanat, Nuray
Advisor dc:contributor.advisor
  • Jenkins, David

Rights

Language dc:language.dcterms_iso639_2
eng

Identifiers

dc:identifier.*
Identifier
uk.bl.ethos.684638

Chain of custody

source
Harvested from
White Rose University Consortium
Base URL
etheses.whiterose.ac.uk/cgi/oai2
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
related terms
citation

Yavuzkanat, Nuray. Development of Novel Scintillation Detection Techniques for Use in Nuclear Physics and Medical Applications. doctoral thesis, University of York, 2016.