Back to search

University of Sheffield

Two-Colour Temperature Measurement Based on High Speed Imaging

Abstract

dc:description.abstract

This thesis reports an optical temperature measurement based on the two-colour method using colour-band filters to examine the application of it in novel ways. This technique uses a high-speed camera to detect the visible radiation from grey bodies. As a result of using the R and G channels, this modified two-colour method was found to be calibrated well with the standard temperature. The uniqueness of this research is the use of SiC fibre as a grey body emitter, allowing the temperature measurement to carry out in the situation of the hot gas and flame with soot deficiency. By conducting the numerical analysis the time taken to achieve the thermal equilibrium between the fibre and its adjacent gas was found to be in a few milliseconds.

Degree

thesis:*
Name dc:type.qualificationname
Ph.D
Level dc:type.qualificationlevel
doctoral
Grantor dc:publisher.institution
University of Sheffield
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • ma, zhen
Advisor dc:contributor.advisor
  • Yang, Zhang

Rights

Language dc:language.dcterms_iso639_2
eng

Identifiers

dc:identifier.*
Identifier
uk.bl.ethos.714319

Chain of custody

source
Harvested from
White Rose University Consortium
Base URL
etheses.whiterose.ac.uk/cgi/oai2
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
related terms
citation

ma, zhen. Two-Colour Temperature Measurement Based on High Speed Imaging. doctoral thesis, University of Sheffield, 2016.