Back to search

University of Leeds

A Biomagnetic Field Mapping System for Detection of Heart Disease in a Clinical Environment

Abstract

dc:description.abstract

This PhD was inspired by the clinical demand for a system to triage chest pain and the untapped diagnostic potential of magnetocardiography (MCG) to reliably detect silent ischaemic heart disease, which is responsible for the highest mortality rate of any single disease category. The aim was to develop a low cost and portable biomagnetic field mapping system capable of differentiating between healthy and diseased hearts within an unshielded hospital environment. This entailed the development of a system based on an array of magnetometers with sufficient sensitivity (104fT/ Hz at 10Hz) and noise rejection performance (68.4 ± 3.9 dB) to measure the small magnetic field associated with the heart beat, the magneocardiogram, within a much larger background noise. The array of induction coil magnetometers (ICM) we developed had sufficient sensitivity and were robust to high amplitude noise. These sensors were also cheap to manufacture and capable of operating on battery power, allowing a low cost, portable device to be developed. The key element that allowed us to achieve unshielded operation was the development of an algorithmic spatial filter, used as a substitute to operation within a magnetically shielded room. This coherent noise rejection (CNR) algorithm exploits the difference in spatial coherence between the local cardiac signals and the distant background noise sources. The observed coherence width during a clinical trial of the system within a hospital ward was 2.8 ± 0.9 × 10 6 mm 2 . This allowed us to capture MCG signals with a signal to noise ratio of SNR QRS = 0.93 ± 4.43dB. The performance of CNR was found to improve by 9dB per order of magnitude increase in environmental spatial coherence width. The coherence width can be increased by changes to hospital architecture, electromagnetic field regulation and device design optimisation. The thesis also explores a variety of approaches to obtain binary diagnostic information from MCG, from traditional statistical learning on manually engineered features to machine learning. I found that machine learning techniques, in particular convolutional neural networks (CNN), were able to capture more diagnostic information than traditional techniques and achieved world class prediction accuracy of 88% on the clinical trial dataset.

Degree

thesis:*
Name dc:type.qualificationname
Ph.D
Level dc:type.qualificationlevel
doctoral
Grantor dc:publisher.institution
University of Leeds
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Mooney, John William
Advisor dc:contributor.advisor
  • Varcoe, Benjamin T.H.

Rights

Language dc:language.dcterms_iso639_2
eng

Identifiers

dc:identifier.*
Identifier
uk.bl.ethos.770098
Dc Identifier Grantnumber
500010859
EP/N00941X/1

Chain of custody

source
Harvested from
White Rose University Consortium
Base URL
etheses.whiterose.ac.uk/cgi/oai2
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
related terms
citation

Mooney, John William. A Biomagnetic Field Mapping System for Detection of Heart Disease in a Clinical Environment. doctoral thesis, University of Leeds, 2018.