Back to search

University of Sheffield

Dynamic Interactions of a Double-stage Photovoltaic Power Converter: Modelling and Control

Abstract

dc:description.abstract

Photovoltaic (PV) systems are a promising renewable source to achieve green energy targets and be part of the electricity generation. Lots of efforts have been devoted to increase the penetration level of PV systems and its share in the generated electricity. Power quality is one of the challenges that impact the penetration level of PV systems. It is important to ensure high power quality from PV systems to allow more installations to the grid. So, PV power quality issues have to be addressed properly. It was reported that the poor power quality of the PV systems might be caused by many reasons such as the large amount of PV power fluctuation, the low level of current from the PV system, and large populations of PV inverters. In addition to the aforementioned reasons, recently it was suggested that perturb and observe (P&O) controller is another source of harmonics which result in a deprived PV power quality. This newly reported problem is based on experimental observations without full understanding of the generation mechanism of these harmonics in the PV system, the relation between the P&O controller design and the generated harmonics, and the effect of these harmonics on the rest of the system. Thus, in-depth analysis of the harmonics in PV systems due to P&O controller and a solution to eliminate these harmonics are demanded. Therefore, in this research an investigation is carried out to explore P&O related harmonics in a double-stage grid-connected PV system. First, regarding the P&O related harmonics full explanation of how harmonics are generated due to the perturbing nature of the P&O controller is provided, a modelling approach is suggested to identify the frequency and the amplitude of the variations in the DC bus due to the P&O controller, the effect of different factors (e.g. weather conditions, system parameters, system operating point, and P&O architecture) on the induced harmonics are investigated. Secondly, regarding the effect of the P&O related harmonics on the rest of the system an intense simulation analysis is provided to explore the possible effect of the P&O related harmonics on increasing the interaction between the system power stages. This can help to set system design recommendations and guidelines such as sizing the dc-link capacitance and designing the system controllers. Finally, a novel mitigation solution is proposed to supress the P&O related harmonics. That can help to reduce the dynamic interaction between system power stages and improve the power quality of the PV system.

Degree

thesis:*
Name dc:type.qualificationname
Ph.D
Level dc:type.qualificationlevel
doctoral
Grantor dc:publisher.institution
University of Sheffield
Year dc:date.issued
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Alsharif, Rabab
Advisors dc:contributor.advisor
  • Odavic, Milijana
  • Atallah, Kais

Rights

Language dc:language.dcterms_iso639_2
eng

Identifiers

dc:identifier.*
Identifier
uk.bl.ethos.778791

Chain of custody

source
Harvested from
White Rose University Consortium
Base URL
etheses.whiterose.ac.uk/cgi/oai2
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
related terms
citation

Alsharif, Rabab. Dynamic Interactions of a Double-stage Photovoltaic Power Converter: Modelling and Control. doctoral thesis, University of Sheffield, 2019.