Back to search

University of Leeds

Anatomically informed image reconstruction for time of flight positron emission tomography

Abstract

dc:description.abstract

Positron emission tomography (PET) has an important role in disease diagnosis, drug development and patient management. PET images are accompanied with computed tomography (CT) or magnetic resonance (MR) to provide the complementary structural information. GE SIGNA PET/MR is the state-of-the-art clinical scanner that aims at combining time of flight-PET (TOF-PET) with anatomical and soft-tissue MR imaging. This work aims at modelling the mathematical and physical processes of TOF-PET data for the GE SIGNA PET/MR within an open-source software, software for tomographic image reconstruction (STIR). This work further examines the developments made to implement the acquisition model using typical (ordered subsets expectation maximisation (OSEM)) and advanced iterative algorithms (TOF-OSEM and TOF-kernelised expectation maximisation (TOF-KEM)). TOF-PET improves conventional PET imaging as it localises the event along the line of response (LOR) within a small region with an uncertainty which is calculated using the timing resolution of the detectors. It demonstrates robustness despite the presence of small errors, inconsistencies or patient motion in the acquired data. The GE SIGNA PET/MR have a timing resolution of 390 ps. The aim of this work is to exploit TOF-PET and further include the anatomical information from MR images to facilitate robust PET reconstructions. All the developments made in this thesis were compared with the vendor's reconstruction software (GE-toolbox). Real phantom and clinical datasets were used for the analysis. The calculated emission and data corrections using developments made in STIR were in excellent agreement with the GE-toolbox despite the absence of dead-time and decay effects within the current developments. Reconstructions using OSEM and TOF-OSEM algorithms demonstrated a good agreement with the GE-toolbox concerning quantitative, resolution and structural based analysis. TOF-KEM reconstructions demonstrated a slight improvement in quantification as compared to TOF-OSEM with STIR. The thesis demonstrates the first instance of real data reconstruction for TOF-PET data using TOF-OSEM and TOF-KEM algorithms. The developments made in this thesis provide a platform to investigate the effects of a novel reconstruction algorithm, TOF-KEM on the dose and scan time reduction using real clinical datasets.

Degree

thesis:*
Name dc:type.qualificationname
Ph.D
Level dc:type.qualificationlevel
doctoral
Grantor dc:publisher.institution
University of Leeds
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Wadhwa, Palak
Advisors dc:contributor.advisor
  • Tsoumpas, Charalampos
  • Buckley, David

Rights

Language dc:language.dcterms_iso639_2
eng

Identifiers

dc:identifier.*
Identifier
uk.bl.ethos.816889
Dc Identifier Grantnumber
MR/M01746X/1

Chain of custody

source
Harvested from
White Rose University Consortium
Base URL
etheses.whiterose.ac.uk/cgi/oai2
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
related terms
citation

Wadhwa, Palak. Anatomically informed image reconstruction for time of flight positron emission tomography. doctoral thesis, University of Leeds, 2020.