Back to search

University of Leeds

Slender reinforced concrete columns.

Abstract

dc:description.abstract

The analysis of slender reinforced concrete columns is complicated because the non-linearities o f the materials (caused by the cracking o f concrete and time-dependent effects) are combined with the geometric non-linearity which characterises the behaviour of such columns. A simple, analytical method based on a graphical technique, originally proposed by B eal, is developed. The method takes account o f the material and geometric non-linearities and allows rapid and accurate analysis o f slender pin-ended reinforced concrete columns, concentrically or eccentrically loaded, without the need for iterative procedures or simplification o f section behaviour. The method allows for sustained load effects and enables the reduction in the short-term ultimate capacity to be predicted. The theoretical analysis is backed by nineteen short and long-term full-scale tests on pinned reinforced concrete columns having slenderness ratios between 18 and 63, loaded eccentrically. The experimental results substantiated the fact that instability is the primary failure criterion for slender columns; and it occurs at relatively low compressive concrete strains of the order o f 0.001-0.002. Material failure eventually follows, but for slenderness ratios o f 33 and above this requires considerable bending to occur. Creep was found to strongly influence the buckling load; with a sustained load of 60% of short-term capacity, creep causes a considerable reduction in the load capacity of a slender column and can be as much as 40%. Initial imperfections are inevitable during column construction. This was accounted for in the theoretical approach and the results obtained demonstrated the sensitivity of slender columns to such imperfections. The accuracy of the proposed method is further established when comprehensive comparisons are made with the experimental work o f other investigators. Significant improvement is noted over the existing design methods in BS8110 and ACI318. The design procedures adopted in the two Codes are based on strength calculations which are proved to be almost irrelevant for slender columns. The BS8110 approach was found to be unsafe in predicting the long-term buckling loads o f the columns tested because it does not make allowance for creep effects. This is in contrast to ACI318 recommendations which were found to be conservative in predicting the failure loads.

Degree

thesis:*
Name dc:type.qualificationname
Ph.D
Level dc:type.qualificationlevel
doctoral
Grantor dc:publisher.institution
University of Leeds
Year dc:date.issued
1991

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Khalil, Nariman Jaber
Advisor dc:contributor.advisor
  • Cusens, A.R

Rights

Language dc:language.dcterms_iso639_2
eng

Identifiers

dc:identifier.*
Identifier
uk.bl.ethos.305374

Chain of custody

source
Harvested from
White Rose University Consortium
Base URL
etheses.whiterose.ac.uk/cgi/oai2
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
related terms
citation

Khalil, Nariman Jaber. Slender reinforced concrete columns.. doctoral thesis, University of Leeds, 1991.