Abstract
dc:description.abstractThe present thesis discusses the problem of magnetic actuation and control applied to millimetre-scale robots for endoluminal procedures. Magnetic actuation, given its remote manipulation capabilities, has the potential to overcome several limitations of current endoluminal procedures, such as the relatively large size, high sti�ness and limited dexterity of existing tools. The application of functional forces remotely facilitates the development of softer and more dexterous endoscopes, which can navigate with reduced discomfort for the patient. However, the solutions presented in literature are not always able to guarantee smooth navigation in complex and convoluted anatomical structures. This thesis aims at improving the navigational capabilities of magnetic endoluminal robots, towards achieving full autonomy. This is realized by introducing novel design, sensing and control approaches for magnetically actuated soft endoscopes and catheters. First, the application of accurate closed-loop control to a 1 Internal Permanent Magnet (IPM) endoscope was analysed. The proposed approach can guarantee better navigation capabilities, thanks to the manipulation of every mechanical Degree of Freedom (DOF) - 5 DOFs. Speci�cally, it was demonstrated that gravity can be balanced with su�cient accuracy to guarantee tip levitation. In this way contact is minimized and obstacle avoidance improved. Consequently, the overall navigation capabilities of the endoscope were enhanced for given application. To improve exploration of convoluted anatomical pathways, the design of magnetic endoscopes with multiple magnetic elements along their length was introduced. This approach to endoluminal device design can ideally allow manipulation along the full length; facilitating full shape manipulation, as compared to tip-only control. To facilitate the control of multiple magneto-mechanical DOFs along the catheters' length, a magnetic actuation method was developed based on the collaborative robotic manipulation of 2 External Permanent Magnets (EPMs). This method, compared to the state-of-the-art, facilitates large workspace and applied �eld, while guaranteeing dexterous actuation. Using this approach, it was demonstrated that it is possible to actuate up to 8 independent magnetic DOFs. In the present thesis, two di�erent applications are discussed and evaluated, namely: colonoscopy and navigational bronchoscopy. In the former, a single-IPM endoscopic approach is utilized. In this case, the anatomy is large enough to permit equipping the endoscope with a camera; allowing navigation by direct vision. Navigational bronchoscopy, on-the-other-hand, is performed in very narrow peripheral lumina, and navigation is informed via pre-operative imaging. The presented work demonstrates how the design of the magnetic catheters, informed by a pre-operative Computed Tomography (CT) scan, can mitigate the need for intra-operative imaging and, consequently, reduce radiation exposure for patients and healthcare workers. Speci�cally, an optimization routine to design the catheters is presented, with the aim of achieving follow-the-leader navigation without supervision. In both scenarios, analysis of how magnetic endoluminal devices can improve the current practice and revolutionize the future of medical diagnostics and treatment is presented and discussed.
Degree
thesis:*- Name dc:type.qualificationname
- Ph.D
- Level dc:type.qualificationlevel
- doctoral
- Grantor dc:publisher.institution
- University of Leeds
- Year dc:date.issued
- 2022
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Pittiglio, Giovanni
- Advisor dc:contributor.advisor
-
- Valdastri, Pietro
- ORCID person:identifier.orcid
Rights
- Language dc:language.dcterms_iso639_2
- eng
Identifiers
dc:identifier.*- Identifier
- uk.bl.ethos.858670
- Dc Identifier Grantnumber
-
EP/R045291/1
818045