Back to search

University of Sheffield

The Development of Instrumentation to Increase the Accessibility and Throughput of Single-Molecule FRET

Abstract

dc:description.abstract

Current drug discovery approaches use high-throughput ensemble methods combined with large libraries of small molecules to measure and quantify the drug-ligand interactions. These methods currently suffer from ensemble averaging, meaning only the average conformational state is measured. Diffusion-based single-molecule Förster resonance energy transfer (FRET) can measure tightly bound drug candidates with high affinity and has the potential to overcome the limitations of these methods by identifying multiple conformational states and, in the process, minimises sample consumption. However, this technique suffers from high acquisition times which limits the throughput of this method. Furthermore, high instrument costs and a lack of open-source hardware have limited the use of single-molecule FRET to specialists. We aim to extend this method by making it affordable, easy to use and applicable for high throughput drug discovery. Here we present a commercially available, affordable, single-spot, single-molecule microscope that allows flexibility for single-molecule researchers. In addition, an open-source, compact and cost-effective excitation module for single-molecule imaging and spectroscopy is presented. By comparing this module to commercially available lasers, this excitation module reported a similar degree in accuracy of single-molecule FRET measurements for three well studied oligonucleotides. By combining common confocal microscopy principles with single�molecule methods we also studied the performance of a multi-spot setup for high-throughput single-molecule FRET. Here we observed single-molecules at high frame rates (1000 frames per second) and observed FRET in a multi-spot setup using a transmission electron microscopy (TEM) grid. We envisage that this research will make this powerful single-molecule technique more widely available for users in academia and industry and more applicable to the drug discovery process.

Degree

thesis:*
Name dc:type.qualificationname
Ph.D
Level dc:type.qualificationlevel
doctoral
Grantor dc:publisher.institution
University of Sheffield
Year dc:date.issued
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • George, Dylan
Advisors dc:contributor.advisor
  • Craggs, Tim
  • Cadby, Ashley
ORCID person:identifier.orcid

Rights

Language dc:language.dcterms_iso639_2
eng

Identifiers

dc:identifier.*
Identifier
uk.bl.ethos.868610

Chain of custody

source
Harvested from
White Rose University Consortium
Base URL
etheses.whiterose.ac.uk/cgi/oai2
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
related terms
citation

George, Dylan. The Development of Instrumentation to Increase the Accessibility and Throughput of Single-Molecule FRET. doctoral thesis, University of Sheffield, 2022.