Back to search

University of Sheffield

Analysis of Battery Energy Storage for Frequency Response Services

Abstract

dc:description.abstract

As the use of renewable energy sources (RESs) increases worldwide, there is a rising interest in their impacts on power system operation and control. These resources are considered variable, independent, and intermittent by nature and can contribute to power quality, stability, and reliability issues. To overcome such problems, in Great Britain (GB), the National Grid Electricity System Operator (NGESO) – the primary electricity system network operator – has introduced various frequency response services to provide a real-time response to deviations in the grid frequency. Battery Energy Storage Systems (BESS) are considered a good solution to deliver such services to the grid. In this thesis, the control algorithm for a generic BESS has been implemented in Matlab Simulink to deliver frequency response services according to National Grid (NG) specifications. Moreover, this thesis presents a sensitivity analysis of the power-to-energy ratio for Energy Storage Systems (ESS) providing frequency services with respect to availability, compliance against service terms and conditions, and lifetime. It shows that there is a significant difference between the frequency of services and demonstrates that the newer dynamic containment service can be effectively delivered by a higher power-to-energy ratio ESS, offering opportunities for other technologies such as supercapacitors and flywheels. Control methodologies are investigated that exploit the delivery envelopes to manage the state of charge and improve the availability of a battery energy storage system, potentially resulting in higher revenues, an increase in cycle life, and decreased penalty payments. To investigate life-time, different methods to analyse battery operation to provide degradation estimates are presented which are then informed through experimental work. Finally, in this thesis, the financial costs of using GB’s electricity system have been investigated and simulated to provide a comparison between delivering different frequency services.

Degree

thesis:*
Name dc:type.qualificationname
Ph.D
Level dc:type.qualificationlevel
doctoral
Grantor dc:publisher.institution
University of Sheffield
Year dc:date.issued
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ahmouda, Abdulkarim A
Advisors dc:contributor.advisor
  • Gladwin, Dan
  • Foster, Martin

Rights

Language dc:language.dcterms_iso639_2
eng

Identifiers

dc:identifier.*
Dc Identifier Grantnumber
BT/LN/299102400418

Chain of custody

source
Harvested from
White Rose University Consortium
Base URL
etheses.whiterose.ac.uk/cgi/oai2
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
related terms
citation

Ahmouda, Abdulkarim A. Analysis of Battery Energy Storage for Frequency Response Services. doctoral thesis, University of Sheffield, 2023.