Back to search

University of Leeds

Intelligent image-driven motion modelling for adaptive radiotherapy

Abstract

dc:description.abstract

Internal anatomical motion (e.g. respiration-induced motion) confounds the precise delivery of radiation to target volumes during external beam radiotherapy. Precision is, however, critical to ensure prescribed radiation doses are delivered to the target (tumour) while surrounding healthy tissues are preserved from damage. If the motion itself can be accurately estimated, the treatment plan and/or delivery can be adapted to compensate. Current methods for motion estimation rely either on invasive implanted fiducial markers, imperfect surrogate models based, for example, on external optical measurements or breathing traces, or expensive and rare systems like in-treatment MRI. These methods have limitations such as invasiveness, imperfect modelling, or high costs, underscoring the need for more efficient and accessible approaches to accurately estimate motion during radiation treatment. This research, in contrast, aims to achieve accurate motion prediction using only relatively low-quality, but almost universally available planar X-ray imaging. This is challenging since such images have poor soft tissue contrast and provide only 2D projections through the anatomy. However, our hypothesis suggests that, with strong priors in the form of learnt models for anatomical motion and image appearance, these images can provide sufficient information for accurate 3D motion reconstruction. We initially proposed an end-to-end graph neural network (GNN) architecture aimed at learning mesh regression using a patient-specific template organ geometry and deep features extracted from kV images at arbitrary projection angles. However, this approach proved to be more time-consuming during training. As an alternative, a second framework was proposed, based on a self-attention convolutional neural network (CNN) architecture. This model focuses on learning mappings between deep semantic angle-dependent X-ray image features and the corresponding encoded deformation latent representations of deformed point clouds of the patient's organ geometry. Both frameworks underwent quantitative testing on synthetic respiratory motion scenarios and qualitative assessment on in-treatment images obtained over a full scan series for liver cancer patients. For the first framework, the overall mean prediction errors on synthetic motion test datasets were 0.16±0.13 mm, 0.18±0.19 mm, 0.22±0.34 mm, and 0.12±0.11 mm, with mean peak prediction errors of 1.39 mm, 1.99 mm, 3.29 mm, and 1.16 mm. As for the second framework, the overall mean prediction errors on synthetic motion test datasets were 0.065±0.04 mm, 0.088±0.06 mm, 0.084±0.04 mm, and 0.059±0.04 mm, with mean peak prediction errors of 0.29 mm, 0.39 mm, 0.30 mm, and 0.25 mm.

Degree

thesis:*
Name dc:type.qualificationname
Ph.D
Level dc:type.qualificationlevel
doctoral
Grantor dc:publisher.institution
University of Leeds
Year dc:date.issued
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Wijesinghe, W Okandapola Kankanamalage Isuru Suranga
Advisors dc:contributor.advisor
  • Taylor, Zeike
  • Nix, Michael
  • Gooya, Ali
ORCID person:identifier.orcid

Rights

Language dc:language.dcterms_iso639_2
eng

Chain of custody

source
Harvested from
White Rose University Consortium
Base URL
etheses.whiterose.ac.uk/cgi/oai2
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
related terms
citation

Wijesinghe, W Okandapola Kankanamalage Isuru Suranga. Intelligent image-driven motion modelling for adaptive radiotherapy. doctoral thesis, University of Leeds, 2024.