University of York
Development of a Scintillator Cluster Detector and Microcontroller Integrated Detector Circuit
Abstract
dc:description.abstractThis thesis reports on the development of a prototype cluster scintillator detector hermetically sealed in an aluminium housing for use in the HYPATIA array. The HYPATIA array will consist of GaGG and CeBr3(Ce) scintillators, however, this prototype uses four NaI(Tl) crystals to optimise the design and validate the encapsulation process before the final device is constructed. The NaI(Tl) crystals, 30x30x80 mm3 were mounted to 2x2 SiPM arrays. The energy and time resolution, energy calibration and linearity of the detector were measured for each detector element as well as add-back being used for each detector pairing. The long-term performance of the hermetic seal was tested over a two-month period and showed no degradation in detector performance outside of measurement error. The best performing crystal had a FWHM energy resolution of 7.79±0.02% while the FWHM coincidence time resolution between a pair of crystals was 23.1±0.2 ns. A proposal for a redesign of the aluminium housing and associated clamping system is also presented. The redesign aims to minimise the external dimensions of the can and in particular its lid in order to enable the detector to better fit with other detectors of the same design in the HYPATIA array. The suggested redesign allows for a closer packing of the quad clusters in the array, reducing the dead space within the active solid angle of the array from 8.5±0.1% to 2.2±0.4%. Also reported in this thesis is the development of a microcontroller integrated detector circuit. This circuit used an Arduino Nano BLE33 microcontroller on a solderless breadboard with a peak hold circuit. The circuit had a maximum nonlinearity of 1.24±0.03% and an average FWHM channel resolution of 44.5±0.2. The motivation behind this work was to extend the use of the Hypatia cluster into the societal applications regime by enabling a portable, high efficiency scintillator detector. The conclusions from the present study regarding the performance of the prototype cluster detector validate the technological choices for the assembly methods and materials for canning and informs future choices for the final HYPATIA clusters.
Degree
thesis:*- Name dc:type.qualificationname
- M.Sc by research
- Level dc:type.qualificationlevel
- masters
- Grantor dc:publisher.institution
- University of York
- Year dc:date.issued
- 2024
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Barraclough, David
- Advisor dc:contributor.advisor
-
- Paschalis, Stefanos
- ORCID person:identifier.orcid
Rights
- Language dc:language.dcterms_iso639_2
- eng