Fatigue cracking of corroded cast iron pipes exposed to complex loading

Abstract

dc:description.abstract

This Thesis presents the first experimental validation of a model for predicting the fatigue strength of Grey Cast Iron (GCI) pipes that feature corrosion pitting and are subjected to complex load combinations. A unique aspect of this work was the extensive laboratory test programme. Novel experiments were used to investigate the effects of pit geometry and load type on the fatigue strength and leakage behaviour of GCI pipes. The UK water industry has committed to reducing leakage from distribution pipes by 1.4x10^9 litres/day by 2050 to improve water supply drought resilience. This work provides a tool that can compare the leakage failure risk of specific GCI water pipes with a resolution that was not previously possible. Implementing this tool will allow asset managers to proactively replace pipes in a targeted way to reduce leakage.

Degree

thesis:*
Name dc:type.qualificationname
Ph.D
Level dc:type.qualificationlevel
doctoral
Grantor dc:publisher.institution
University of Sheffield
Year dc:date.issued
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • John, Edward
Advisors dc:contributor.advisor
  • Susmel, Luca
  • Boxall, Joby
  • Collins, Richard
  • Bowman, Elisabeth
ORCID person:identifier.orcid

Rights

Language dc:language.dcterms_iso639_2
eng

Identifiers

dc:identifier.*
Dc Identifier Grantnumber
EPSRC funding reference: EP/S023666/1

Chain of custody

source
Harvested from
White Rose University Consortium
Base URL
etheses.whiterose.ac.uk/cgi/oai2
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
related terms
citation

John, Edward. Fatigue cracking of corroded cast iron pipes exposed to complex loading. doctoral thesis, University of Sheffield, 2024.