University of York
Towards analytical applications using SABRE-hyperpolarised benchtop NMR
Abstract
dc:description.abstractBenchtop NMR spectrometers offer an accessible analytical platform due to their low acquisition and operation costs, as well as their portability. However, their lower magnetic field strength (1 - 3 T) results in reduced sensitivity and chemical shift dispersion compared to high-field systems (≥ 7 T), limiting their widespread use in routine analysis. This thesis explores the potential of benchtop NMR in combination with the hyperpolarisation technique signal amplification by reversible exchange (SABRE), as an accessible and sensitive analytical technique. A special focus is placed on 19F NMR measurements to mitigate spectral congestion. Integrating SABRE with the multiplet-refocusing pulse sequence SHARPER led to significant signal-to-noise ratio (SNR) enhancements, as demonstrated in 19F NMR measurements on a set of fluoropyridines exhibiting diverse scalar coupling patterns. By the combined effects of SABRE and SHARPER, SNR enhancements of up to 5700-fold were achieved. A novel variation of the selective SHARPER pulse sequence enabled simultaneous signal isolation and enhancement for each component of a binary mixture, minimising signal loss compared to previous versions. The boost in signal enhancement afforded by SABRE-SHARPER was harnessed to decrease detection limits for this technique, aided by the use of co-substrates to form a stable polarisation transfer catalyst, resulting in a submicromolar limit of detection for a model fluoropyridine target. The use of co-substrates also facilitated the micromolar quantification of this target with an excellent degree of accuracy and precision. The scope for this technique was further explored by probing a fluoroamine target, which contains exchangeable protons and is susceptible to polarisation deviation via SABRE Relay. Although this unwanted process leads to a sensitivity penalty, which can be minimised by deuteration of the exchangeable protons, low micromolar limits of detection and accurate quantification is shown for this analyte. In contrast, fluorocarboxylic acids posed greater challenges. SABRE enhancements were observed exclusively for their carboxylate forms and remained modest, with operational detection limits in the low millimolar range.
Degree
thesis:*- Name dc:type.qualificationname
- Ph.D
- Level dc:type.qualificationlevel
- doctoral
- Grantor dc:publisher.institution
- University of York
- Year dc:date.issued
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Silva Terra, Ana Ines
- Advisor dc:contributor.advisor
-
- Halse, Meghan
- ORCID person:identifier.orcid
Rights
- Language dc:language.dcterms_iso639_2
- eng