University of Sheffield
Use of Recycled Concrete Material from Nuclear Decommissioning for Nuclear Waste Encapsulation
Abstract
dc:description.abstractIn the UK, Portland cement (PC) grouts for radioactive waste encapsulation rely heavily on supplementary cementitious materials (SCMs), ground-granulated blastfurnace slag (GGBS) and pulverised fuel ash (PFA), but long-term UK supply is uncertain. Analysis of 25 primary concrete waste streams in the 2019 UK Radioactive Waste Inventory indicates ~ 2.4 million m³ of waste concrete, whose usable fraction requires characterisation and recovery. This thesis evaluates recycled concrete material (RCM) as a partial SCM replacement. Hydrated PC paste (HCP) and ~ 30-year-old GGBS-PC concrete from Électricité de France (EDF) were assessed. Following separate PC-80HCP particle-size screening, formulations derived from 3:1 SCM:PC references replaced 0–80% of the original SCM component, retaining 25 wt.% fresh PC at a water-to-binder ratio (w/b) of 0.3875. Fresh behaviour, strength, mercury-accessible pore characteristics, and phase assemblage were assessed. Finer HCP reduced bleed and increased strength in the screening system. Replacing 26.7% of the SCM provided a conservative starting point, with greater initial fluidity and formulation-dependent strength and pore-entry trade-offs relative to the reference binders. Higher replacement generally reduced strength and coarsened pore entries. All SCM-PC-RCM formulations met the adopted bleed and setting screens and exceeded 7 MPa at 28 d; the strength benchmark applied at 90 d. Low HCP substitution in PFA-PC produced a small measured mean strength gain alongside hydrate development and net portlandite depletion; individual mechanisms were not isolated. At 28 d, EDF retained higher measured strength and lower mercury-accessible porosity than HCP in GGBS-PC, without consistently finer pore entries. Re-crushing of EDF yielded coarser, relatively aggregate-enriched fractions; individual fraction performance remained untested. Optimisation around 53.3% SCM replacement warrants further investigation. RCM offers a potential route to partial SCM-demand reduction. No radioactive waste was tested; waste-specific compatibility, radionuclide retention, and package-scale performance require further assessment.
Degree
thesis:*- Name dc:type.qualificationname
- Ph.D
- Level dc:type.qualificationlevel
- doctoral
- Grantor dc:publisher.institution
- University of Sheffield
- Year dc:date.issued
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Scammell, Douglas George
- Advisors dc:contributor.advisor
-
- Kinoshita, Hajime
- Hand, Russell
- ORCID person:identifier.orcid
Rights
- Language dc:language.dcterms_iso639_2
- eng
Identifiers
dc:identifier.*- Dc Identifier Grantnumber
- EP/T517835/1