Back to search

University of York

Investigating the use of Radiation Sensors for a Novel Device to Benchmark Lethal Doses of Alpha Radiation on Malignant Cells

Abstract

dc:description.abstract

With cancer rates at an all time high, the demand for novel radiopharmaceutical treatments is increasing rapidly to provide targeted treatment to a range of metastatic and treatment resistant cancers. One promising new approach is Targeted Alpha Therapy (TAT), which utilises alpha emitting radionuclides bound to targeting molecules that attach to the active site of cancer cells to deliver a highly localised and cytotoxic dose of radiation. However, supply issues, unsuitable testing models and slow development rates have significantly limited the progress made in the clinical translation of research into novel TAT radiopharmaceuticals. This project aims to explore the feasibility of using p-n junction photodiodes to produce a novel rapid throughput device for the active measurement of lethal doses of alpha radiation delivered to ex-vivo tumour microenvironments. This was done through three key investigations: The development of a proof-of-concept exposure prototype device that allows the benchmarking of lethal alpha radiation doses delivered to a culture of MDA-MB-231 triple negative breast cancer cells, the experimental detection of the characteristic 241Am energy spectrum through the simulation of the exposure prototype setup, and confirming the both the viability and the response of the MB-231 breast cancer cells on the exposure prototype components and when exposed to radiation. The photodiode investigations demonstrated overall that p-n junctions could potentially be used for active dose measurements in the lethal dose benchmarking setup, where alpha particles were detectable after passing through 13µm of mylar film, 13µm of water and 11 mm of Air with a detected energy range between 1.9 MeV and 2.15 MeV. However, these results carried large uncertainty values due to high noise levels and low signal amplitudes. The viability investigations showed that the MB-231 cells were viable when cultured on the surface of SU-8 patterned Microwells and when cultured in the presence of 3D printed components, but only when soak sterilised for a maximum of 5-minutes in a 70% Ethanol solution. The radiation exposure experiment, however, yielded poor results, where the MB-231 cells detached from the surface of the substrates, during 5- and 10-minute exposures, due to osmotic and oxidative stress as the cell growth solution evaporated. An investigation using cell growth solutions containing 1%, 5% and 10% concentrations of glycerol was conducted to explore whether the impact of the cell growth solution evaporation could be minimised. The 1% glycerol solution demonstrated the only positive result, demonstrating better cell adhesion after 5-minutes, however, the observed cells demonstrated signs of significant stress, indicating cells may detach during longer exposure times. As a result, this experiment indicates that further adaptations to the experimental surface, such as microfluidic hydration channels, are required to improve the viability of cells on the experimental surface so that experimental confirmation of the active dose measurement system can be conducted. Overall, the work presented in this thesis indicates that it could be feasible to implement p-n junction photodiodes as an active dose measurement system in novel dose benchmarking devices, however, significant further research into improving the accuracy of the detected alpha particle energies, improving the cell viability on the experimental surface and further experimentation to validate the repeatability and validity of the determined results are required before the device can undergo complete testing and verification.

Degree

thesis:*
Name dc:type.qualificationname
M.Sc by research
Level dc:type.qualificationlevel
masters
Grantor dc:publisher.institution
University of York
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Locke, William
Advisors dc:contributor.advisor
  • Patil, Dr Samadhan
  • Diget, Dr Christian
  • Brackenbury, Dr Will
  • Malcom, Dr Jodie

Rights

Language dc:language.dcterms_iso639_2
eng

Chain of custody

source
Harvested from
White Rose University Consortium
Base URL
etheses.whiterose.ac.uk/cgi/oai2
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
related terms
citation

Locke, William. Investigating the use of Radiation Sensors for a Novel Device to Benchmark Lethal Doses of Alpha Radiation on Malignant Cells. masters thesis, University of York, 2026.