Back to search

University of Leeds

Natural ventilation and cooling by evaporation in hot-arid climates

Abstract

dc:description.abstract

In hot climates, outside air is too hot during the day. In hot arid climates, low humidity increases discomfort. For comfort, hot air should be cooled before flowing into dwellings and moisture in the moving air increased. For the poor, comfort must be sought cheaply. In places without electricity only 'natural' ventilation is feasible. The air temperature difference between the sunny and the shaded side of a building can be exploited to promote ventilation. Ventilation cooling can be enhanced with an 'evaporative cooling cavity' attached to a dwelling on its shaded side. The cavity has a top external inlet and a bottom internal outlet, and incorporates one or two wet partitions. The air within the cavity, being moist. descends. drawing the outside warm and dry air into the cavity. Evaporation cools the air and raises its humidity. The cool incoming air will reduce inside air temperature and improve comfort. The performance of a typical cavity to induce cooling ventilation by evaporation was investigated theoretically and experimentally with a full scale model. The temperature drop. velocity and relative humidity of the air were measured. The pattern of the air flow in the cavity was observed. The optimum dimensions of the cavity were established. Buoyancy air flow and fan-assisted air flow were analysed in the steady state. Since a convective heat transfer coefficient for air flowing between two parallel vertical surfaces was not found in the literature, appropriate convective heat and surface mass transfer coefficients were derived from measurements. The results show the convective heat transfer coefficient to be independent of the separation of the wet surfaces, and that with separation greater than 3Omm, each wet surface behaves as a 'free' surface. The optimum separation between wet surfaces was assessed, and the water removed by evaporation was determined, and found to be small. The Admittance Method was used to assess comfort. Ventilation and evaporation effectiveness were evaluated. An outlet air velocity of O.3m/s accompanied with a temperature drop of about 6K was achieved. Design proposals for hot arid climates are offered.

Degree

thesis:*
Name dc:type.qualificationname
Ph.D
Level dc:type.qualificationlevel
doctoral
Grantor dc:publisher.institution
University of Leeds
Year dc:date.issued
1990

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Aboul Naga, Mohsen M
Advisors dc:contributor.advisor
  • Fitzgerald, D.
  • Houghton-Evans, W.

Rights

Language dc:language.dcterms_iso639_2
eng

Identifiers

dc:identifier.*
Identifier
uk.bl.ethos.278300

Chain of custody

source
Harvested from
White Rose University Consortium
Base URL
etheses.whiterose.ac.uk/cgi/oai2
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
related terms
citation

Aboul Naga, Mohsen M. Natural ventilation and cooling by evaporation in hot-arid climates. doctoral thesis, University of Leeds, 1990.