Integration and application of passive cooling within a wind tower

Abstract

dc:description.abstract

The aim of this work was to combine low energy heat transfer devices with a passive ventilation terminal to meet the internal comfort criteria in extreme external conditions using non-mechanical means. Heat transfer devices were installed inside the passive terminal of a wind tower unit, highlighting the potential to achieve minimal restriction in the external air flow stream while ensuring maximum contact time, thus optimising the cooling duty of the device. A numerical analysis was conducted using Computational Fluid Dynamics (CFD) software to simulate and analyse the air flow pattern, pressure and temperature distribution around and through the wind tower to a test room. Experimental investigations were carried out using a closed-loop subsonic wind tunnel at 1:10 scale to assess the accuracy of the simulation results. Pressure coefficients distribution, internal air speed and volumetric airflow were measured for a range of external conditions. Smoke visualisation testing enabled the detailed study and analysis of the air flow patterns in and around the wind tower models for different air incident angles. The proposed cooling system was capable of reducing the air temperatures up to 15 K, depending on the configuration and operating conditions. Initial findings revealed that height was not a factor for the proposed heat transfer device arrangement, making it highly viable for commercial roof-mounted wind tower systems. Another advantage of the proposed system over the traditional evaporative cooling systems was the non-reliance on the constant supply of water to continue the cooling cycle. In addition, four-sided and one-sided wind towers were utilised as benchmarks for the CFD investigations. Two heat transfer device (HTD) configurations were incorporated in the wind tower models namely vertical and horizontal HTD arrangements. Furthermore, the CFD model was also used to investigate the effect of the addition of extended surfaces and porous media on the thermal performance of the cooling wind tower. The thermal environment of the test room equipped with a heat transfer device cooling wind tower was simulated and evaluated using Fluent Airpak. The thermal comfort was studied using the PMV index scale. The elements necessary to calculate the PMV and PPD were taken from the initial CFD and experimental results.

Degree

thesis:*
Name dc:type.qualificationname
Ph.D
Level dc:type.qualificationlevel
doctoral
Grantor dc:publisher.institution
University of Leeds
Year dc:date.issued
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Calautit, John Kaiser Santos
Advisor dc:contributor.advisor
  • Hughes, B.R

Rights

Language dc:language.dcterms_iso639_2
eng

Identifiers

dc:identifier.*
Identifier
uk.bl.ethos.595186

Chain of custody

source
Harvested from
White Rose University Consortium
Base URL
etheses.whiterose.ac.uk/cgi/oai2
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
related terms
citation